MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI L06CPU-P Structured Text(ST) Manual L06CPU-P PROGRAMMING Guide Book

MITSUBISHI L06CPU-P Structured Text(ST) Manual L06CPU-P PROGRAMMING Guide Book

Brand: MITSUBISHI
Product model: L06CPU-P
Name: PLC
Sort: PROGRAMMING Guide Book (Structured Text(ST))
File language: English
File size: 2.99MB
Number of input channels: 2Ch.
Differential drive input.
Maximum count rate: pulse/s 500K.
Linear counter function.
Ring counter function.
Uniform output function.
Preset function.
Count invalid function.
Latch counter function.
Sampling counter function.
Periodic pulse counter function.
Flexibly applied to various applications
Combination of functions,
Easy to achieve speed measurement, long measuring function, the single pulse output, the ratio of the set / distribution output, PWM control, cam switch control, such as a wide range of control L06CPU-P Structured Text(ST) Manual L06CPU-P PROGRAMMING Guide Book L06CPU-P
Single pulse.
To trigger the input as a starting point, with a minimum 25ns unit to adjust the ON/OFF time.
The action time deviation of ON/OFF is ns level, so it can achieve high precision control L06CPU-P Structured Text(ST) Manual L06CPU-P PROGRAMMING Guide Book.
Velocity measurement and length measurement
In addition to the measurement of ON width and OFF width,
Can also achieve different sensor ON time difference and other conditions of the measurement.
The high precision measurement of the smallest 25ns unit can be realized.
Delayed output
The output time delay of each channel can be adjusted so that the error output can be realized L06CPU-P Structured Text(ST) Manual L06CPU-P PROGRAMMING Guide Book. Output points: 16 points.
Rated output voltage: DC24V/AC240V.
Rated open and close current: 2A/1 point.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol. Output points: 64 points.
Output type: leakage type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 64 points (I/O distribution: output 64 points).
External wiring connection: 40 pin connector two.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules aree often called L06CPU-P Structured Text(ST) Manual L06CPU-P PROGRAMMING Guide Book.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can alsso be carried out through the RS-485 bus communication,
Remote control switch L06CPU-P Structured Text(ST) Manual L06CPU-P PROGRAMMING Guide Book.
Communication protocol is a standard Modbus protocol or custom protocol.
Related products
MITSUBISHI
cpu module
L26CPU-PBT
MITSUBISHI cpu module L26CPU-PBT
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L26CPU-P
MITSUBISHI cpu module L26CPU-P
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L02SCPU-P
MITSUBISHI cpu module L02SCPU-P
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L02CPU-P
MITSUBISHI cpu module L02CPU-P
"Universal output function: source type. Prog