Output points: 32 points.
Output type: leakage type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 32 points (I/O distribution: output 32 points).
External wiring connection mode: 40 pin connector L06CPU-CM MELSAP-L Manual L06CPU-CM Programming Manual.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called
L06CPU-CM
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol L06CPU-CM MELSAP-L Manual L06CPU-CM Programming Manual. Output points: 8 points (independent of all points).
Rated output voltage: DC24V/AC240V.
Rated open and close current: 2A/1 point.
Public side mode: no public side (all points of independent contact).
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal L06CPU-CM MELSAP-L Manual L06CPU-CM Programming Manual.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol. Input points: 16 points.
Rated input voltage: AC100 ~ 120V.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: 16 points).
External wiring connection: 18 point terminal.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm llinkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the parrt can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on L06CPU-CM MELSAP-L Manual L06CPU-CM Programming Manual L06CPU-CM MELSAP-L Manual L06CPU-CM Programming Manual.