MITSUBISHI
Home >> Products >> MITSUBISHI >> L series PLC >> CPU and accessories >> CPU >> L02CPU-CM | MITSUBISHI cpu module L02CPU-CM

L02CPU-CM | MITSUBISHI cpu module L02CPU-CM

MITSUBISHI L02CPU-CM Manual And Instructions
L02CPU-CM datasheetPDF datasheet
L02CPU-CM Common InstructionsProgramming Manual
L02CPU-CM Special InstructionsProgramming Manual
L02CPU-CM Application FunctionsProgramming Manual
L02CPU-CM Common InstructionsProgramming Manual
L02CPU-CM Structured Text(ST)PROGRAMMING Guide Book
L02CPU-CM Structured TextProgramming Manual
L02CPU-CM MELSAP-LProgramming Manual
L02CPU-CM Structured TextProgramming Guide
L02CPU-CM PID Control InstructionsProgramming Manual
L02CPU-CM Special InstructionsProgramming Manual
L02CPU-CM Common InstructionsProgramming Manual
L02CPU-CM Application FunctionsProgramming Manual
L02CPU-CM ApplicationUser's Manual
L02CPU-CM Structured TextProgramming Manual

MITSUBISHI L02CPU-CM Product information and technical parameters:
Brand: MITSUBISHI
Name: cpu module
Model: L02CPU-CM
"Universal output function: leakage type.
Program capacity: 20K step.
Basic operations processing speed: 40ns.
Communication interface: USB/Ethernet.
Control mode: stored procedure repeated operation.
Input / output points: 1024 points.
End cap.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ".
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators. "

Output channel number: 4ch.
Output voltage: DC - 10 ~ 10V.
Output current: DC0 ~ 20mA.
Conversion speed: 20 s/ch.
Resolution: 1/20000.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm MITSUBISHI L02CPU-CM.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm L02CPU-CM
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement MITSUBISHI L02CPU-CM.
High speed, smooth continuous analog output.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulated according to the set conversion period.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output MITSUBISHI L02CPU-CM. RS-232, RS-422/485.
Transmission speed: 230.4kbps.
MC protocol.
Communication protocol support function.
Can only be used on the ch1 side.
Device for immediate communication
Communication protocol support function through Works2 GX,
Can easily set the required agreement with the other equipment communication.
In addition, only the communication protocol library is required to select the equipment to be carried out,
Immediate connection.
The creation and editing of communication protocols are simple and easy to implement, even if there is no connection equipment in the communication protocol library,
Can also simply create a corresponding protocol for communication.
The content of the communication protocol that can be created in the list,
Can also be simply edited. Temperature measurement resistor input.
Number of input channels: 4ch.
Detection function of broken wire with heater.
Standard control.
Heating and cooling control.
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode.
Temperature regulation mode.
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function.
It can control temperature uniform, to ensure that the control object no local burning or thermal expansion.
No idle running, with energy saving effect, can reduce operating costs.
Can make multi loop to reach the target value (SV) of the same time.
By setting the simultaneous heating of the channel group, up to 2 groups of units, respectively, at the same time warming.
It is very effective to uuse the control object that does not want to heat up to the time of arrival error L02CPU-CM.
Applicable to a variety of systems.
Sampling period switching function.
Sampling period can be selected from 250ms/4ch and 500ms/4ch.
Equipped with temperatture input mode L02CPU-CM.
The temperature control module can be used as a temperature input module.
By setting the switch, you can easily change the input mode.


...More relevant models >>>>