MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI L02SCPU-CM Structured Text(ST) Manual L02SCPU-CM PROGRAMMING Guide Book

MITSUBISHI L02SCPU-CM Structured Text(ST) Manual L02SCPU-CM PROGRAMMING Guide Book

Brand: MITSUBISHI
Product model: L02SCPU-CM
Name: PLC
Sort: PROGRAMMING Guide Book (Structured Text(ST))
File language: English
File size: 2.99MB
Open collector output.
Axis of control: 2.
Maximum output pulse: pulse/s 200k.
Location data: 600 data / axis.
Max link distance: 2m.
With the parameter setting, the synchronization control can be easily realized. Do not need to write complex procedures.
Start / stop with synchronous control of the shaft L02SCPU-CM Structured Text(ST) Manual L02SCPU-CM PROGRAMMING Guide Book.
Synchronous control of the axis and the positioning of the axis can coexist L02SCPU-CM
Through the clutch, the movement of the main shaft can be transferred to the output shaft.
Simple implementation of synchronization control.
Cam control is more simple
Cam data can easily create a variety of patterns.
Can be simple to achieve the gear, shaft, transmission, cam and other mechanical mechanisms to replace the software synchronization control L02SCPU-CM Structured Text(ST) Manual L02SCPU-CM PROGRAMMING Guide Book.
It is not subject to the limitation of the concept of the electronic cam control so far, and can use the cam with high degree of freedom.
The stroke, speed, acceleration and beat can be confirmed on the graph, and the setting is carried out at the same time.
Can also be through the cam data thumbnail display, easy to confirm the cam data has been created L02SCPU-CM Structured Text(ST) Manual L02SCPU-CM PROGRAMMING Guide Book.
Can import and export the cam data in CSV format. "Universal output function: source type.
Program capacity: 260K step.
Basic operations processing speed: 9.5ns.
Communication interface: USB/Ethernet (built-in CC-Link function).
Program capacity: 20K step.
Control mode: stored procedure repeated operation.
Input / output points: 4096 points.
End cap.
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precisionn workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurrement L02SCPU-CM Structured Text(ST) Manual L02SCPU-CM PROGRAMMING Guide Book L02SCPU-CM Structured Text(ST) Manual L02SCPU-CM PROGRAMMING Guide Book.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ". "
Related products
MITSUBISHI
cpu module
L02SCPU-P
MITSUBISHI cpu module L02SCPU-P
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L02SCPU-CM
MITSUBISHI cpu module L02SCPU-CM
"Universal output function: leakage type. Pro
MITSUBISHI
cpu module
L02CPU-CM
MITSUBISHI cpu module L02CPU-CM
"Universal output function: leakage type. Pro
MITSUBISHI
cpu module
L06CPU-CM
MITSUBISHI cpu module L06CPU-CM
"Universal output function: leakage type. Pro