Output points: 32 points.
Output type: leakage type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 32 points (I/O distribution: output 32 points).
External wiring connection mode: 40 pin connector L02CPU-CM Common Instructions Manual L02CPU-CM Programming Manual.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called
L02CPU-CM
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol L02CPU-CM Common Instructions Manual L02CPU-CM Programming Manual. Input points: 32 points.
Input voltage: DC24V.
Enter the public side of the way: 32 points / public.
Output form: transistor output (source).
Output points: 32 points.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have
Output common way: 32 point / common.
Input / output occupied points: 32 points (I/O distribution: input and output mixed 32 points) L02CPU-CM Common Instructions Manual L02CPU-CM Programming Manual.
External wiring connection: 40 pin connector two.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system.
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged.
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged.
3, RS-485 interface with 600W lightning protection and surge protection function, with 3000V photoelectric isolatioon L02CPU-CM Common Instructions Manual L02CPU-CM Programming Manual.
4, the use of Modbus protocol, good general, can be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convennient and flexible L02CPU-CM Common Instructions Manual L02CPU-CM Programming Manual.
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability.