Function: input / output module (internal service power supply).
Input / output points: 32 points
Input points: 16 points.
Output points: 16 points.
DC5V internal consumption current: 965mA.
DC24V internal consumption current: 250mA.
Input / output mode: DC input (drain / source) / transistor (drain) FX3U-48MT/DS MODBUS Serial Communication Edition Manual FX3U-48MT/DS USER'S MANUAL.
In order to extend the input output of the device
FX3U-48MT/DS
Also has a built-in power supply products.
The maximum number of points for the input and output is 256.
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points. Max input / output points: 80 points.
Supply voltage: 100 - 240VAC.
Input points: 40 points FX3U-48MT/DS MODBUS Serial Communication Edition Manual FX3U-48MT/DS USER'S MANUAL.
Output points: 40 points.
Output type: relay.
Power consumption: 70VA.
Weight (kg):1.2.
Size (WxHxD) mm:285x90x87.
Since the FX2n series have the following features: the maximum range of inclusive of the standard features, program execution faster, the full complement of communication function, suitable for different countries in the world, and the power to meet a large number of special function modules of individual needs,
It can provide maximum flexibility and control capability for your factory automation applications FX3U-48MT/DS MODBUS Serial Communication Edition Manual FX3U-48MT/DS USER'S MANUAL.
Control 16~256 point.
Built in 8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 7.5KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%).
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and elecctrical FX3U-48MT/DS MODBUS Serial Communication Edition Manual FX3U-48MT/DS USER'S MANUAL.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120%% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load FX3U-48MT/DS MODBUS Serial Communication Edition Manual FX3U-48MT/DS USER'S MANUAL.