MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI FX3U-16MT-DS Positioning Control Edition Manual FX3U-16MT-DS USER'S MANUAL

MITSUBISHI FX3U-16MT-DS Positioning Control Edition Manual FX3U-16MT-DS USER'S MANUAL

Brand: MITSUBISHI
Product model: FX3U-16MT-DS
Name: PLC
Sort: USER'S MANUAL (Positioning Control Edition)
File language: English
File size: 5.86MB
Power: 37kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity.
At the same time the installation options in the use of 75kW and above motor FX3U-16MT-DS Positioning Control Edition Manual FX3U-16MT-DS USER'S MANUAL FX3U-16MT-DS (the IP55 series has a built-in DC reactor.)
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) Function extension board for USB communication.
DC5V power consumption: 0mA. Power: 3.7kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted FX3U-16MT-DS Positioning Control Edition Manual FX3U-16MT-DS USER'S MANUAL.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table.
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling FX3U-16MT-DS Positioning Control Edition Manual FX3U-16MT-DS USER'S MANUAL.
MYS type resistor can be used. But please pay attention to the allowable brake use rate.
Do not remove the terminal P/+ and P1 between the short circuit chip, in addition to connecting the DC reactor.
The installation of thermal relay, to avoid overheating and burn the braking resistor. For the operation panel (FR-DU08) between the connector and the connecting cable."MITSUBISHI inverter FR-F740P series.
Voltage level: three phase 400V.
Frequency converter capacity: 560KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor.
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mainly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FX3U-16MT-DS Positioning Control Edition Manual FX3U-16MT-DS USER'S MANUAL.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FX3U-16MT-DS Positioning Control Edition Manual FX3U-16MT-DS USER'S MANUAL. "
Related products
MITSUBISHI
PLC
FX2N-16MT-DSS
MITSUBISHI PLC FX2N-16MT-DSS
Max input / output points: 16 points. Power s
MITSUBISHI
CC-Link connection module
FX3U-16CCL-M
MITSUBISHI CC-Link connection module FX3U-16CCL-M
Station type: Master station. Maximum numer
MITSUBISHI
PLC
FX3U-128MT/ES-A
MITSUBISHI PLC FX3U-128MT/ES-A
Max input / output points: 128 points. Supply
MITSUBISHI
1 axis positioning control module
FX3U-1PG
MITSUBISHI 1 axis positioning control module FX3U-1PG
Input signal power: 40mA. DC24V Axis of contr