Power: 15kw.
Voltage: 400V.
The surge voltage of the motor can be suppressed when the 400V motor is driven by a frequency converter.
Motor suitable for 5.5 to 37kW. Total points: 32 points.
Input points: 16 points.
Input mode: DC24V (drain type).
Output points: 16 points.
Output form: Transistor (drain type) FX3G-40MT/ESS Positioning Control Edition Manual FX3G-40MT/ESS USER'S MANUAL.
Connection status: connector
FX3G-40MT/ESS
In order to extend the input output of the device.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256.
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points. MITSUBISHI inverter FR-A740 series FX3G-40MT/ESS Positioning Control Edition Manual FX3G-40MT/ESS USER'S MANUAL.
Voltage level: 3 phase 400V.
Frequency converter capacity: 37KW.
Frequency converter is the application of frequency conversion technology and micro electronics technology, by changing the motor operating power frequency mode to control the AC motor power control equipment.
The converter is composed of rectifier (AC), filter, inverter (DC), braking unit, driving unit, micro processing unit of the detection unit FX3G-40MT/ESS Positioning Control Edition Manual FX3G-40MT/ESS USER'S MANUAL.
Inverter by the internal IGBT to adjust the output power supply voltage and frequency,
According to the actual needs of the motor to provide the required power supply voltage, and then achieve the purpose of energy saving, speed control, in addition to the,
Inverter has a lot of protection functions, such as over current, over voltage, overload protection and so on. The adapter with PT100 type temperature sensor (FX3U- - racy -BD)The operation, monitoring, parameter modification and other operations can be carried out by computer or PLC.Input points: 16 points.
Outtput points: 16 points FX3G-40MT/ESS Positioning Control Edition Manual FX3G-40MT/ESS USER'S MANUAL.
Output form: transistor.
Connected programmable logic controller: FX1NC, FX2NC, FX3UC.
FX2NC expansion module can be directly connected to the FX1NCC, FX2NC, PLC FX3UC on the expansion of the input and output FX3G-40MT/ESS Positioning Control Edition Manual FX3G-40MT/ESS USER'S MANUAL.
Do not need to connect the cable and so on, therefore can carry on the compact expansion.