Can be isolated to obtain DC24/48/100V, AC100/200V input signal.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Power: 3.7kw.
Voltage: 200V.
Purpose: high frequency braking resistor.
The braking ability provided by the braking capacity is larger than that provided by the external braking resistor FX2NC-485ADP Data Communication Edition Manual FX2NC-485ADP USER'S MANUAL FX2NC-485ADP
Can also be connected without built-in brake transistor inverter.
Three types of discharge resistors are available.
Please select according to the required braking torque. Function: input / output module (internal service power supply).
Input / output points: 32 points
Input points: 16 points.
Output points: 16 points.
DC5V internal consumption current: 965mA FX2NC-485ADP Data Communication Edition Manual FX2NC-485ADP USER'S MANUAL.
DC24V internal consumption current: 250mA.
Input / output mode: DC input (drain / source) / transistor (drain).
In order to extend the input output of the device.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256.
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points FX2NC-485ADP Data Communication Edition Manual FX2NC-485ADP USER'S MANUAL. MITSUBISHI inverter FR-E720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 1.5KW.
In order to ensure the reliability of production, all production machinery in the design of power with drive, there is a certain amount of surplus.
When the motor can not run under full load, in addition to meet the requirements of power driven,
The surplus torque increases the active power consumption, resulting in the waste of electric energy.
Speed control method of fan and pump equipment traditional by regulating the entrance or exitt of the baffle, valve opening to regulate air flow and water flow
, the input power is large, and a large amount of energy consumption in the baffle, the valve in the processs of closure FX2NC-485ADP Data Communication Edition Manual FX2NC-485ADP USER'S MANUAL FX2NC-485ADP Data Communication Edition Manual FX2NC-485ADP USER'S MANUAL.
When using variable frequency control, if the flow rate is reduced, the speed of the pump or fan can be reduced to meet the requirements.
Related products
MITSUBISHI
High speed counter module
FX2NC-1HC
MITSUBISHI High speed counter module FX2NC-1HC
Maximum frequency: 50kHz. Input points: 1 poi
MITSUBISHI
PLC
FX2NC-96MT-D/UL
MITSUBISHI PLC FX2NC-96MT-D/UL
Max input / output points: 96 points. Power s
MITSUBISHI
Extension module
FX2NC-16EX-DS
MITSUBISHI Extension module FX2NC-16EX-DS
Input points: 16 points. Power supply: the a