CC-Link interface module.
PLC FX can be used as the CC-LINK remote device station connection.
If using CC-LINK type FX2N-16CCL-M system master module,
So just PLC CC-LINK can build FX system. Power: 22kw.
Purpose: to suppress the power harmonics.
Connected to the inverter input, can be used to improve the power factor, reduce the input side of the high harmonic current FX2N-32MT-ESS/UL Manual FX2N-32MT-ESS/UL PROGRAMMING MANUAL II
FX2N-32MT-ESS/UL
According to the motor power used to select AC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) "MITSUBISHI inverter series: FR-A846.
Voltage level: three phase 400V.
Power: 37kw.
SLD converter rated current: 93A.
Structure and function: IP55 counterpart FX2N-32MT-ESS/UL Manual FX2N-32MT-ESS/UL PROGRAMMING MANUAL II.
Type: CA.
Substrate coating: have.
Built in DC reactor.
Easy to operate, simple settings.
We have prepared a series of equipment and functions for you to work in any place to meet the life cycle of the product.
Allegedly, the motor power consumption accounted for about half of the total power generated by manufacturing industry consumption.
How to achieve energy efficiency in the plant without affecting the productivity FX2N-32MT-ESS/UL Manual FX2N-32MT-ESS/UL PROGRAMMING MANUAL II.
Less energy consumption and more output FR-A800 series inverter will help you to have both fish and bear''s paw"
Parameters and frequency settings can be modified in the program.
Inverter control, for example, by the input signal to trigger the operation of the inverter, based on the operation of the inverter
The status of the signal output, as well as the monitor output and so on, can be customized according to the requirements.
The control of each machine can be done separately by the frequency converter, and the control of the dispersion is also carried out.
Through combining with the real-time clock function can realize the automatic operation (in option FR-LU08). "RS-232C communication adapter.
(need FX1N-CNV-BD).
(FX1S and FX1N host general). MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 22KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%).
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical FX2N-32MT-ESS/UL Manual FX2N-32MT-ESS/UL PROGRAMMING MANUAL II.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120%% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load FX2N-32MT-ESS/UL Manual FX2N-32MT-ESS/UL PROGRAMMING MANUAL II.