MITSUBISHI FR-V540-15K-CH BASIC Manual FR-V540-15K-CH INSTRUCTION MANUAL

Brand: MITSUBISHI
Product model: FR-V540-15K-CH
Name: VECTOR INVERTER
Sort: INSTRUCTION MANUAL (BASIC)
File language: English
File size: 0.00MB
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Analog output expansion board (1 channel).Input and output points: 20 points.
Power supply: AC100-240V.
Input points: 12 points.
Output points: 8 points.
Output form: relay output.
Power consumption: 20W FR-V540-15K-CH BASIC Manual FR-V540-15K-CH INSTRUCTION MANUAL.
Weight: 0.4KG.
Outline dimension: 75x90x75mm FR-V540-15K-CH
A new application model.
FX3SA is a basic model on the basis of the basic performance of FX1S above the expansion of the expansion of the new model.
FX3SA is applicable to all kinds of fields of small scale equipment which need to simulate the quantity and function of MODBUS and Ethernet.
Basic models suitable for small scale control.
Compact but powerful,
At the same time, the analog quantity and communication function, etc FR-V540-15K-CH BASIC Manual FR-V540-15K-CH INSTRUCTION MANUAL. . Through a series of holes available to install FR-A800 using the original FR-A500 series.MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 18.5KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%) FR-V540-15K-CH BASIC Manual FR-V540-15K-CH INSTRUCTION MANUAL.
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load. MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 7.5KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible.
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used. For a sinngle phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced FR-V540-15K-CH BASIC Manual FR-V540-15K-CH INSTRUCTION MANUAL FR-V540-15K-CH BASIC Manual FR-V540-15K-CH INSTRUCTION MANUAL.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft.
Related products
MITSUBISHI
3 phase 400V converter
FR-F740P-15K-CHT
MITSUBISHI 3 phase 400V converter FR-F740P-15K-CHT
"MITSUBISHI inverter FR-F740P series. Voltage
MITSUBISHI
3 phase 400V converter
FR-F740-15K-CHT
MITSUBISHI 3 phase 400V converter FR-F740-15K-CHT
"MITSUBISHI inverter FR-F740 series. Voltage
MITSUBISHI
3 phase 400V converter
FR-A740-15K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-15K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-L740-15K-CHT
MITSUBISHI 3 phase 400V converter FR-L740-15K-CHT
MITSUBISHI inverter FR-L740 series. Voltage l