MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI FR-PU07 Manual FR-PU07 Instruction manual

MITSUBISHI FR-PU07 Manual FR-PU07 Instruction manual

Brand: MITSUBISHI
Product model: FR-PU07
Name: INVERTER
Sort: Instruction manual
File language: English
File size: 2.35MB
Max input / output points: 14 points.
Power supply voltage: 24VDC.
Input points: 8 points.
Output points: 6 points.
Output type: relay.
Power consumption (W): 6.5.
Weight (kg):0.22.
Size (WxHxD) mm:60x90x49.
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types FR-PU07 Manual FR-PU07 Instruction manual.
This type of PLC is mainly used in all of the digital input, digital output control point of the device FR-PU07
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O FR-PU07 Manual FR-PU07 Instruction manual.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication.
All equipment is digital input and output point.
The total I/O points are not more than 30 points, and the input points are less than 16, the output points are less than 14.
Its MT series of PLC can drive 2 way servo or stepper, commonly used in the control system for a simple manipulator FR-PU07 Manual FR-PU07 Instruction manual. Connecting cable for handheld GOT and PLC.
Cable length: 1.5 meters.
Application: RS-422 connection (A/QnA series). MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 315kw.
SLD converter rated current: 683A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
The motor efficiency is not changed in the previous optimal excitation control,
At the same time, the newly developed advanced optimal excitation control can obtain larger torque at startup.
No need to adjust the parameters (plus deceleration time or torque, etc.), in a short time to speed up to a certain speed,
Can be carried out to maximize the efficiency of energy-saving drive motor.
The automatic tuning function of the loop constant of the motor is not consistent with the constant of the motor, the motor of other manufacturers, and the length of wiring is too long,
Optimum operating characteristic drive motor.
In the state oof the sensor can not only drive the high efficiency and energy saving motor and PM motor (MM-EFS), but also can drive other companies induction motor and PM motor (permanent magnet synchronous motor) FR-PU07 Manual FR-PU07 Instruction manual.
Othher manufacturers of induction motors, can also be automatically tuned to achieve the best excitation control, thus expanding the use of energy saving FR-PU07 Manual FR-PU07 Instruction manual.
Related products
MITSUBISHI
3 phase 400V converter
FR-A740-110K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-110K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l
MITSUBISHI
3 phase 200V converter
FR-F720-2.2K
MITSUBISHI 3 phase 200V converter FR-F720-2.2K
MITSUBISHI inverter FR-F720 series. Voltage l
MITSUBISHI
PLG cable
FR-V7CBL30
MITSUBISHI PLG cable FR-V7CBL30
Length: 30 meters. Cale manufacturing specif