Max input / output points: 64 points.
Supply voltage: 100 - 240VAC.
Input points: 32 points.
Output points: 32 points.
Output type: relay.
Power consumption: 45W.
Weight (kg):1.0.
Size (WxHxD) mm:220x90x86.
Faster and more efficient. Support high speed control and network communication, and have the function of data recording FR-A846-00380-2-60 DETAILED Manual FR-A846-00380-2-60 Instruction manual
FR-A846-00380-2-60
High speed, large capacity, multi-function high-end machine.
FX3U supports high speed processing, CC-Link communication, network communication, analog control and advanced positioning system.
Connected to the CC-Link, including the remote I/O, the maximum input and output control points up to 384 points,
Can correspond to a variety of field needs, the use of its scalability and flexibility to expand the scope of application of the control system FR-A846-00380-2-60 DETAILED Manual FR-A846-00380-2-60 Instruction manual.
Third generation high function micro programmable controller.
High speed, high efficiency, high performance, large capacity, and new features.
Built in high speed processing and positioning.
Control points: maximum 256 points.
Use CC-Link remote I/O for 384 points. RS-232C communication adapter.
(need FX1N-CNV-BD).
(FX1S and FX1N host general) FR-A846-00380-2-60 DETAILED Manual FR-A846-00380-2-60 Instruction manual. Length: 5 meters.
Operation panel or parameter unit connection line. MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 11kw.
SLD converter rated current: 63A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Compatibility with existing models.
Transducer installation size and FR-F700 (P) series of the same, so you do not need to worry about the replacement operation.
(rectifier separation type will vary)
Also, but also through the use of options (FR-A8TAT), FR-F700 (P) series installed control loop terminal station.
Built in 2 PID arithmetic. In the inverter can be PID control of the motor state at the same time, used in the control of the external machine.
No external PID controller is used to control the external machine, so the system cost can be reduced. Input / output mode: transistor output (drain).
Output points: 8 points.
DC5V internal consumption current: 75mA.
DC24V internal consumption current: 75mAA FR-A846-00380-2-60 DETAILED Manual FR-A846-00380-2-60 Instruction manual.
In order to extend the input output of the device.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256.
Expansion modulee: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points FR-A846-00380-2-60 DETAILED Manual FR-A846-00380-2-60 Instruction manual.