MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI FR-A740-30K-CHT Manual FR-A740-30K-CHT PLC FUNCTION PROGRAMMING MANUAL

MITSUBISHI FR-A740-30K-CHT Manual FR-A740-30K-CHT PLC FUNCTION PROGRAMMING MANUAL

Brand: MITSUBISHI
Product model: FR-A740-30K-CHT
Name: INVERTER
Sort: PLC FUNCTION PROGRAMMING MANUAL
File language: English
File size: 3.53MB
Protocol: SLMP, TCP/IP, UDP, SNTP.
Communication mode: full duplex / half duplex.
At the same time can open a few: 4 connection.
Weight: 0.3kg.
Can be low cost will be connected to the FX3 series Ethernet.
Support data monitoring, can monitor the basic unit through the computer browser,
Remote maintenance can be carried out by Works2 GX in a place far from the scene FR-A740-30K-CHT Manual FR-A740-30K-CHT PLC FUNCTION PROGRAMMING MANUAL FR-A740-30K-CHT
Connect FX3SA, FX3S, FX3GA, FX3G, FX3U host, you need to convert the adapter or function expansion board. Power: 37kw.
Voltage: 200V.
There are 100% braking torque output in continuous regeneration, which can correspond to the continuous regeneration operation of the pipeline control.
There is no need to install the braking unit for each frequency converter, which can reduce the comprehensive space and reduce the comprehensive cost FR-A740-30K-CHT Manual FR-A740-30K-CHT PLC FUNCTION PROGRAMMING MANUAL.
Renewable energy can be used for other frequency converter, excess energy back to the grid, to achieve energy saving. "MITSUBISHI inverter FR-F720P series.
Voltage level: three phase 200V.
Frequency converter capacity: 30KW.
When the ring is opened, the frequency converter is provided with a load of the motor when the motor is operated with a load at a given frequency,
The range of the motor speed in the rated slip ratio (1%~5%) changes FR-A740-30K-CHT Manual FR-A740-30K-CHT PLC FUNCTION PROGRAMMING MANUAL.
For the requirements of relatively high precision, even if the load changes are also required to operate at a given speed of the occasion,
Inverter with PG feedback function can be used (selection).
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mainly used in the testing equipment of instrument aand meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FR-A740-30K-CHT Manual FR-A740-30K-CHT PLC FUNCTION PROGRAMMING MANUAL.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FR-A740-30K-CHT Manual FR-A740-30K-CHT PLC FUNCTION PROGRAMMING MANUAL. "
Related products
MITSUBISHI
3 phase 400V converter
FR-A740-315K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-315K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-A740-250K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-250K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-A740-37K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-37K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-A740-45K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-45K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l