MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 30kw.
SLD converter rated current: 154A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
PID target value can be set directly from the operator panel. Flexible change settings.
In the 1 inverter, through the PID control of parallel connection pump (up to 4 units) can adjust the amount of water and so on FR-A740-280K-CHT datasheet PDF catalog FR-A740-280K-CHT PDF datasheet
FR-A740-280K-CHT
1 pumps driven by parallel connection of the pump machine, in addition to the pump for power frequency drive.
The number of power frequency driven pump, according to the automatic adjustment of water.
The liquid crystal panel options (FR-LU08) can be converted to a more intuitive display unit% units FR-A740-280K-CHT datasheet PDF catalog FR-A740-280K-CHT PDF datasheet.
Through the use of wind, temperature and other familiar units can be simple to maintain and adjust the display. Maximum file size: 512MB.
Data form: CSV form.
Weight: 0.3kg.
PLC data can be saved in the form of CF to CSV.
1, can save up to 254, 32767 row of data.
2, save the CSV file can be read through the table count software, and in the form of graphics display, ease of analysis FR-A740-280K-CHT datasheet PDF catalog FR-A740-280K-CHT PDF datasheet.
PLC can be read through the collected data.
Long time to collect data, through the file FIFO function,
You can automatically generate new files and automatically overwrite the old files, to achieve the continuous collection of data.
Record the historical data before and after the alarm,
In a file to collect data buffer storage file will play a.
FX3U, FX3UC version 2.61 or more can be used, the need to connect the FX3U when the expansion board.
The communication function expansion board and the communication special adapter are the same, the communication occupies 1 channels. MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 0.4KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible.
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used. For a single phasse motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced FR-A740-280K-CHT datasheet PDF catalog FR-A740-280K-CHT PDF datasheet FR-A740-280K-CHT datasheet PDF catalog FR-A740-280K-CHT PDF datasheet.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft.