460此ID下载地址不存在3--/downloadfile/309manual_Y992D08401b.pdf MITSUBISHI F1-40MR-UL Sink input type Manual F1-40MR-UL INSTRUCTION MANUAL - MITSUBISHI
MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI F1-40MR-UL Sink input type Manual F1-40MR-UL INSTRUCTION MANUAL

MITSUBISHI F1-40MR-UL Sink input type Manual F1-40MR-UL INSTRUCTION MANUAL

Brand: MITSUBISHI
Product model: F1-40MR-UL
Name: PLC
Sort: INSTRUCTION MANUAL (Sink input type)
File language: English
File size: 0.00MB
Can be used to locate the wiring between drives.
Trunk terminal available for external input signal. Max input / output points: 16 points.
Supply voltage: 100 - 240VAC.
Input points: 8 points.
Output points: 8 points.
Output type: relay.
Power consumption: 20W.
Weight (kg):0.6.
Size (WxHxD) mm:130x90x87 F1-40MR-UL Sink input type Manual F1-40MR-UL INSTRUCTION MANUAL.
Since the FX2n series have the following features: the maximum range of inclusive of the standard features, program execution faster, the full complement of communication function, suitable for different countries in the world, and the power to meet a large number of special function modules of individual needs,
It can provide maximum flexibility and control capability for your factory automation applications F1-40MR-UL Sink input type Manual F1-40MR-UL INSTRUCTION MANUAL F1-40MR-UL
Control 16~256 point.
Built in 8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type) F1-40MR-UL Sink input type Manual F1-40MR-UL INSTRUCTION MANUAL.
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable. Analog input points: 4 points (thermocouple, PT, constant voltage input).
Output points: transistor output 4 points, 4 point CT input.
Weight: 0.4KG.
Temperature sensor with 4CH input control output,
Double position control, standard PID control,
Heating and cooling PID control, cascade control.
By using the combination of the analog output module,
PID control of voltage or current can be realized.
New with cascade control. Through the master / slave station of the 2 controllers,
According to the temperature change caused by external disturbance, the temperature can be adjusted quickly.
Can connect FX3GA/FX3G, FX3GE, FX3U series.
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-IPS-5V. MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 3.7kw.
SLD converter rated current: 25A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight).
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume off equipment) F1-40MR-UL Sink input type Manual F1-40MR-UL INSTRUCTION MANUAL.
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network F1-40MR-UL Sink input type Manual F1-40MR-UL INSTRUCTION MANUAL.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps.