MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI AJ71QC24N-R2 Modem Function Additional Version Manual AJ71QC24N-R2 User's Manual

MITSUBISHI AJ71QC24N-R2 Modem Function Additional Version Manual AJ71QC24N-R2 User's Manual

Brand: MITSUBISHI
Product model: AJ71QC24N-R2
Name: Serial Communications Module
Sort: User's Manual (Modem Function Additional Version)
File language: English
File size: 40.12MB
Input type: DC input, negative public end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: transistor output, source.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/0 AJ71QC24N-R2 Modem Function Additional Version Manual AJ71QC24N-R2 User's Manual AJ71QC24N-R2 5A.
External connection: 1 line /1 line type.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool AJ71QC24N-R2 Modem Function Additional Version Manual AJ71QC24N-R2 User's Manual. For A6TBXY36/A6TBXY54/A6TBX70E (common cathode; drain type) long 1m.Input and output points: 480 points.
Input / output data points: 480 points.
Program capacity: 8k.
Basic command processing speed (LD command) s:1.25.
RAM memory capacity: 32K, power supply.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage AJ71QC24N-R2 Modem Function Additional Version Manual AJ71QC24N-R2 User's Manual.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
User program storage capacity: it is a measure of how much the user application can store the number of iindicators AJ71QC24N-R2 Modem Function Additional Version Manual AJ71QC24N-R2 User's Manual.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General llogical operation instructions each account for 1 words AJ71QC24N-R2 Modem Function Additional Version Manual AJ71QC24N-R2 User's Manual. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Related products
MITSUBISHI
Serial communication module
AJ71QC24N-R4
MITSUBISHI Serial communication module AJ71QC24N-R4
RS-422 1 channel, RS-422/485 1 channel. Trans
MITSUBISHI
Serial communication module
AJ71QC24-R2
MITSUBISHI Serial communication module AJ71QC24-R2
RS-232 2 channel. Transfer speed: 0.3-19.2kp
MITSUBISHI
Serial communication module
AJ71QC24
MITSUBISHI Serial communication module AJ71QC24
RS-232 1 channel, RS-422/485 1 channel. Trans
MITSUBISHI
Serial communication module
AJ71QC24N
MITSUBISHI Serial communication module AJ71QC24N
RS-232 1 channel, RS-422/485 1 channel. Trans