MITSUBISHI AJ71QC24-R4 Modem Function Additional Version Manual AJ71QC24-R4 User's Manual

Brand: MITSUBISHI
Product model: AJ71QC24-R4
Name: Serial Communications Module
Sort: User's Manual (Modem Function Additional Version)
File language: English
File size: 40.12MB
Input points: 32 points.
Input voltage and current: 7mA DC24V.
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 24 points.
Output voltage: DC24V/AC240V, 2A/1 point, 5A/1 common end.
Output response time: 12ms.
Output type: relay output.
8 point /1 a public side AJ71QC24-R4 Modem Function Additional Version Manual AJ71QC24-R4 User's Manual.
34 point terminal station AJ71QC24-R4
PLC is introduced by the relay control technology after the development of micro processing technology,
Can be easily and reliably used for switching control.
As the analog quantity can be converted into digital quantity, the number of digital quantity is just a number of switching value,
Therefore, after the conversion of analog, PLC can also be reliable for processing control AJ71QC24-R4 Modem Function Additional Version Manual AJ71QC24-R4 User's Manual.
Because the continuous production process often has the analog quantity, the analog quantity control is sometimes called process control.
Analog quantity is not electricity, and PLC can only handle digital quantity, quantity of electricity.
All to realize the conversion between them to have the sensor, the analog quantity into a number of power.
If this power is not standard, but also through the transmitter,
The non-standard power into a standard electrical signal, such as 1-5V, 4-20mA, 0-10V, etc AJ71QC24-R4 Modem Function Additional Version Manual AJ71QC24-R4 User's Manual. .
At the same time, there is also an analog input unit (A/D),
Transform these standard electrical signals into digital signals,
The analog output unit (D/A), in order to transform the digital quantity after PLC processing into analog quantity -- standard electric signal.
So the standard telecommunication number, the conversion between the number of operations to use a variety of computing.
This requires the resolution of the analog unit and the standard electrical signal. Output type: transistor source / drain type.
Output points: 8 points.
Load voltage: DC5/12/24/48.
Load current: 2A.
Connection mode: terminal row.
Common public end points: 1.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequencce,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order AJ71QC24-R4 Modem Function Additional Version Manual AJ71QC24-R4 User's Manual.
So, sometimes also known as the order control.
And seqquential control is divided into manual, semi-automatic or automatic AJ71QC24-R4 Modem Function Additional Version Manual AJ71QC24-R4 User's Manual.
And the control principle is decentralized, centralized and hybrid control three.
Related products
MITSUBISHI
Serial communication module
AJ71QC24N-R4
MITSUBISHI Serial communication module AJ71QC24N-R4
RS-422 1 channel, RS-422/485 1 channel. Trans
MITSUBISHI
Network module
AJ71QE71N3-T
MITSUBISHI Network module AJ71QE71N3-T
10BASE-T. For Q mode. When communicating in t
MITSUBISHI
Serial communication module
AJ71QC24N-R2
MITSUBISHI Serial communication module AJ71QC24N-R2
RS-232 2 channel. Transmission speed: 2 chann
MITSUBISHI
Ethernet module
AJ71QE71N-B5T
MITSUBISHI Ethernet module AJ71QE71N-B5T
Ethernet network module 10BASE-T/10BASE5 Equi