MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI AJ71C22 Manual AJ71C22 User's Manual

MITSUBISHI AJ71C22 Manual AJ71C22 User's Manual

Brand: MITSUBISHI
Product model: AJ71C22
Name: Multidrop link unit
Sort: User's Manual
File language: English
File size: 1.96MB
Cable length: 1.2 meters.
Extending cable to connect CPU main substrate and extended substrate,
According to the model can provide different cable length,
If you need to connect the AnN type expansion substrate is required,
Selection of A1SC05NB (A1SC07NB) cable. Input type: DC input, positive common end AJ71C22 Manual AJ71C22 User's Manual.
Input points: 8 points.
Enter the response time: 1.5ms the following AJ71C22
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/0.5A.
External connection: 3 line /2 line type.
Spring clip terminal.
Do not need to be tightened further or locked with screws, which can reduce the working hours of wiring AJ71C22 Manual AJ71C22 User's Manual.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module.
When installing the module can choose to use the DIN guide rail or screw mounting.
Can be used for the 3 wire sensor input wiring. Output points: 16 points.
Voltage: DC12/24V.
OFF leakage current: 0 AJ71C22 Manual AJ71C22 User's Manual. 1mA.
Output type: transistor output (type sink).
Response time: 2ms.
8 points / a common end.
20 point terminal station.
With short circuit protection.
With the surge absorber.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC AJ71C22 Manual AJ71C22 User's Manual.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation AJ71C22 Manual AJ71C22 User's Manual.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
Related products
MITSUBISHI
Computer link module
AJ71C24
MITSUBISHI Computer link module AJ71C24
RS-232:1, RS-422/485:1. Transmission speed: 0
MITSUBISHI
SI/QSI fiber optic cable module
AJ72QLP25
MITSUBISHI SI/QSI fiber optic cable module AJ72QLP25
SI/QSI/H-PCF/ wide range H-PCF fier optic ca
MITSUBISHI
Ethernet module
AJ71QE71N-B5T
MITSUBISHI Ethernet module AJ71QE71N-B5T
Ethernet network module 10BASE-T/10BASE5 Equi
MITSUBISHI
Coaxial cable module
AJ72LR25
MITSUBISHI Coaxial cable module AJ72LR25
Remote I/O controller, coaxial cale, coaxial