MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI A975GOT-TBD SW4D5C-GOTR-PACKE compatible Connection System Manual Manual A975GOT-TBD User's Manual

MITSUBISHI A975GOT-TBD SW4D5C-GOTR-PACKE compatible Connection System Manual Manual A975GOT-TBD User's Manual

Brand: MITSUBISHI
Product model: A975GOT-TBD
Name: touch screen
Sort: User's Manual (SW4D5C-GOTR-PACKE compatible Connection System Manual)
File language: English
File size: 2.74MB
Output type: transistor output, drain type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 1 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup A975GOT-TBD SW4D5C-GOTR-PACKE compatible Connection System Manual Manual A975GOT-TBD User's Manual A975GOT-TBD
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool. GI fiber optic cable.
Double circuit.
MELSECNET (II) (remote I/O station).
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program A975GOT-TBD SW4D5C-GOTR-PACKE compatible Connection System Manual Manual A975GOT-TBD User's Manual.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system A975GOT-TBD SW4D5C-GOTR-PACKE compatible Connection System Manual Manual A975GOT-TBD User's Manual.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc.. Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 3 wire.
Sensor connector type (E-CON type).
Using industry standard E-CON type.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. Screw terminal table type.
Voltage / current output module.
Number of channels: 2 channels.
Number of stations: 1 stops.
Station type: remote equipment station.
MITSUBISHI PLC hardware implementation
Hardware implementation is mainly for the control cabinet and other hardware design and field construction.
Design control cabinet and the operating table and other parts of the electrical wiring diagram and wiring diagram.
Electrical interconnection diagram of each part of the design system.
According to the construction drawings of the site wiring, and carry out a detailed inspection.
Because the program design and hardware implementation can be carried out at the same time,
So the design cycle of the MITSUBISHI PLC control system can be greatly reduced.
MITSUBISHI PLC online debugging.
On-line debugging is the process that will through the simulation debugging to further carry on the on-line unification to adjust.
On-line debugging process should be step by step,
Froom MITSUBISHI PLC only connected to the input device, and then connect the output device, and then connect to the actual load and so on and so on stepp by step A975GOT-TBD SW4D5C-GOTR-PACKE compatible Connection System Manual Manual A975GOT-TBD User's Manual A975GOT-TBD SW4D5C-GOTR-PACKE compatible Connection System Manual Manual A975GOT-TBD User's Manual.
If you do not meet the requirements, the hardware and procedures for adjustment.
Usually only need to modify the part of the program can be.