Output type: transistor output, drain type.
Output points: 32 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 2 wire.
Spring clip terminal.
Do not need to be tightened further or locked with screws, which can reduce the working hours of wiring A960GOT-EBA Extended/Option Functions Manual Manual A960GOT-EBA Operating Manual
A960GOT-EBA
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module.
When installing the module can choose to use the DIN guide rail or screw mounting.
Can be used for the 3 wire sensor input wiring. Input type: AC.
Input points: 16 points.
Input voltage: AC200-240V.
Input current: 11mA.
Connection mode: terminal row A960GOT-EBA Extended/Option Functions Manual Manual A960GOT-EBA Operating Manual.
Common common point: 16.
The instruction list programming language is a programming language similar to assembly language mnemonic,
As well as assembly language by the operation code and the number of operations.
In the case of the computer for the PLC handheld programmer compile user program.
At the same time, the programming language of the instruction list corresponds to the ladder diagram programming language,
In PLC programming software can be converted to each other A960GOT-EBA Extended/Option Functions Manual Manual A960GOT-EBA Operating Manual. Figure 3 is the instruction sheet corresponding to the ladder diagram of figure 2PLC.
The characteristics of instruction table programming language is used to represent mnemonic operation function,
Easy to remember, easy to grasp;
In the handheld programmer on the keyboard using the mnemonic representation, easy to operate, can be programmed in computer;
There is a one-to-one correspondence between the ladder diagram and the ladder diagram. Its characteristics are basically consistent with the ladder diagram language. Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 2 wire.
According to the external cconnection mode and the external equipment input and output specifications,
Choose from a rich product lineup A960GOT-EBA Extended/Option Functions Manual Manual A960GOT-EBA Operating Manual.
Finger protection through the upper part of the terminal,,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool A960GOT-EBA Extended/Option Functions Manual Manual A960GOT-EBA Operating Manual.