MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI A953GOT-LBD Connection System Manual Manual A953GOT-LBD User's Manual

MITSUBISHI A953GOT-LBD Connection System Manual Manual A953GOT-LBD User's Manual

Brand: MITSUBISHI
Product model: A953GOT-LBD
Name: touch screen
Sort: User's Manual (Connection System Manual)
File language: English
File size: 4.71MB
Output type: transistor output, drain type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 1 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup A953GOT-LBD Connection System Manual Manual A953GOT-LBD User's Manual A953GOT-LBD
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool. Analog RGB input system.
Applicable model: A985GOT-V. Output points: 32 points.
Voltage: AC100 ~ 240V.
OFF leakage current: 3mA.
Output type: bidirectional thyristor output A953GOT-LBD Connection System Manual Manual A953GOT-LBD User's Manual.
Response time: 0.5Hz+1ms.
8 points / a common end.
50 point terminal station.
With the surge absorber.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read A953GOT-LBD Connection System Manual Manual A953GOT-LBD User's Manual.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance tto price ratio, a reasonable choice of PLC A953GOT-LBD Connection System Manual Manual A953GOT-LBD User's Manual.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation A953GOT-LBD Connection System Manual Manual A953GOT-LBD User's Manual.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
Related products