MITSUBISHI A73CPUP21-S3 Dedicated Instructions Manual A73CPUP21-S3 Programming Manual

Brand: MITSUBISHI
Product model: A73CPUP21-S3
Name: PLC
Sort: Programming Manual (Dedicated Instructions)
File language: English
File size: 17.11MB
Input points: 16 points.
Input voltage and current: 240V ~ 10mA AC100.
Input response time: 35ms.
16 point /1 a public side.
Output points: 12 points.
Output voltage: AC100 ~ 240V.
OFF leakage current: 3mA.
Output response time: 0.5Hz+1ms.
Output type: bidirectional thyristor output.
8 point /1 a public end, 4 points / a public end A73CPUP21-S3 Dedicated Instructions Manual A73CPUP21-S3 Programming Manual A73CPUP21-S3
36 point terminal station.
With short circuit protection.
With the surge absorber.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points A73CPUP21-S3 Dedicated Instructions Manual A73CPUP21-S3 Programming Manual.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process A73CPUP21-S3 Dedicated Instructions Manual A73CPUP21-S3 Programming Manual.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of thee PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc A73CPUP21-S3 Dedicated Instructions Manual A73CPUP21-S3 Programming Manual. .
In general, a reversible DC drivee system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points A73CPUP21-S3 Dedicated Instructions Manual A73CPUP21-S3 Programming Manual.
Related products
MITSUBISHI
Moving CPU unit
A73CPUR21-S3
MITSUBISHI Moving CPU unit A73CPUR21-S3
Special multi axis positioning controller for
MITSUBISHI
Moving CPU unit
A73CPUP21
MITSUBISHI Moving CPU unit A73CPUP21
Multi axis positioning controller. Optical da
MITSUBISHI
CPU unit
A2ACPUP21-S3
MITSUBISHI CPU unit A2ACPUP21-S3
Input and output points: 512 points. Input /
MITSUBISHI
Moving CPU unit
A73CPU-S1
MITSUBISHI Moving CPU unit A73CPU-S1
Multi axis positioning controller. Program ca