MITSUBISHI A2USCPU-S1 Common Instructions Manual A2USCPU-S1 Programming Manual

Brand: MITSUBISHI
Product model: A2USCPU-S1
Name: Programmable Logic Controller
Sort: Programming Manual (Common Instructions)
File language: English
File size: 3.29MB
Optional features of memory card (A/FX compatible).
2MB extended memory.
Applicable models: A985 (-V) /975/970/A960GOT (-B) /A956WGOT. Output points: 24 points.
Voltage: DC12/24V.
OFF leakage current: 0.1mA.
Output type: transistor output (type sink).
Response time: 2ms.
8 point /1 a public side.
36 point terminal station A2USCPU-S1 Common Instructions Manual A2USCPU-S1 Programming Manual .
With the surge absorber A2USCPU-S1
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal A2USCPU-S1 Common Instructions Manual A2USCPU-S1 Programming Manual .
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points A2USCPU-S1 Common Instructions Manual A2USCPU-S1 Programming Manual .
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points. Type of input: DC source.
Input points: 16 points.
Input voltage: DC24.
Input current: 7mA.
Connection mode: terminal row.
Common common point: 16.
Functional block diagram language is a kind of PLC programming language, which is similar to digital logic circuit.
The function module is used to represent the function of the module,
Different function modules have different functions.
Functional module figure programming language features: functional block diagram programming language is characterized by a functional module for the unit,
Analysis and understanding of the control scheme is simple and easy: function module is to use graaphical form of expression,
Intuitive, for a digital logic circuit based on the design of the staff is very easy to master the programming;
Control system with complex scale and coomplex control logic,
Because the function module diagram can clearly express the function relation, the programming debugging time is greatly reduced A2USCPU-S1 Common Instructions Manual A2USCPU-S1 Programming Manual A2USCPU-S1 Common Instructions Manual A2USCPU-S1 Programming Manual .
Related products
MITSUBISHI
CPU unit
A2USHCPU-S1
MITSUBISHI CPU unit A2USHCPU-S1
I/O points: 1024. Processing speed: 0.09 sec/
MITSUBISHI
CPU unit
Q2ASCPU-S1
MITSUBISHI CPU unit Q2ASCPU-S1
Input and output points: 1024 points. Input /
MITSUBISHI
Motion CPU module
Q172DCPU-S1
MITSUBISHI Motion CPU module Q172DCPU-S1
Upgraded version. Control axis: maximum 8 axe