MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI A2USCPU Manual A2USCPU User's Manual

MITSUBISHI A2USCPU Manual A2USCPU User's Manual

Brand: MITSUBISHI
Product model: A2USCPU
Name: PLC
Sort: User's Manual
File language: English
File size: 10.30MB
DC input points: 2 points.
Input voltage and current: 7mA, DC24V.
Input response time: 10ms.
2 point /1 a public side.
Positive / negative sharing.
Output points: 2 points.
Output voltage and current: DC24V/AC240V, 2A/1 point, 4A/1 common end.
Output response time: 2ms.
2 point /1 a public side.
Output form: relay A2USCPU Manual A2USCPU User's Manual.
16 point terminal station.
MITSUBISHI PLC protection and chain procedures A2USCPU
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations.
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system A2USCPU Manual A2USCPU User's Manual.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc..
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program A2USCPU Manual A2USCPU User's Manual.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation. Type of input: DC source.
Input points: 32 points.
Input voltage: DC24.
Input current: 7mA.
Connection mode: terminal row.
Common common point: 32.
Sequential function flow chart language is designed to satisfy the sequential logic control.
The process of sequential process action is divided into steps and transformation conditions,
According to the transfer condition, the control system is distributed in the function flow sequence,
Step by step according to the sequence of actions.
Each step represents a control function, represented by the box.
In the box, the ladder logic is used to complete the task of the corresponding control function.
This programming language makes the program structure clear and easy to read and maintain,
Greatly reduce the programming workload, shorten the programming and debugging time.
Used in the system of the size of the school, procedures for more complex occasions.
Sequence function flow chart programming language features: to function as the main line, in accordance with the functional flow of the order of distrribution, clear, easy to understand the user program,
Avoid the defect of ladder diagram or other languages,
At the same time, the use of ladder language to avoid the use of ladder programming,
Due to the compllicated mechanical interlock, the structure of the user program is complex and difficult to understand,
User program scan time is also greatly reduced A2USCPU Manual A2USCPU User's Manual A2USCPU Manual A2USCPU User's Manual.
Related products
MITSUBISHI
CPU unit
Q2ASHCPU
MITSUBISHI CPU unit Q2ASHCPU
Input and output points: 512 points. Input /
MITSUBISHI
With Ethernet CPU
Q100UDEHCPU
MITSUBISHI With Ethernet CPU Q100UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
General purpose CPU
Q10UDHCPU
MITSUBISHI General purpose CPU Q10UDHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
Motion controller
Q170MCPU
MITSUBISHI Motion controller Q170MCPU
Axis of control: 16. Compact Q170MCPU integra