The use of A1STA32 can significantly reduce the wiring time I/O 32 type of connector assembly,
Neither welding, without thread stripping,
It only needs to cut a wire and insert the wire into the terminal hole of the A1STA32,
A1STA32 in the blade will cut wire insulation surface,
To make contact and hold a good conductor A273UHCPU  SV22(VIRTUAL MODE) Manual A273UHCPU  Programming Manual. Input points: 16 points A273UHCPU 
Input voltage and current: 3/7mA DC12/24V.
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 12 points.
Output voltage: AC100 ~ 240V.
OFF leakage current: 3mA.
Output response time: 0.5Hz+1ms.
Output type: bidirectional thyristor output.
8 point /1 a public end, 4 points / a public end.
36 point terminal station A273UHCPU  SV22(VIRTUAL MODE) Manual A273UHCPU  Programming Manual.
With short circuit protection.
With the surge absorber.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points A273UHCPU  SV22(VIRTUAL MODE) Manual A273UHCPU  Programming Manual.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc A273UHCPU  SV22(VIRTUAL MODE) Manual A273UHCPU  Programming Manual. .
In general, a reversible DC drivee system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points A273UHCPU  SV22(VIRTUAL MODE) Manual A273UHCPU  Programming Manual.