Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI A1SX80 Manual A1SX80 User's Manual

MITSUBISHI A1SX80 Manual A1SX80 User's Manual

Brand: MITSUBISHI
Product model: A1SX80
Name: I/O Module
Sort: User's Manual
File language: English
File size: 5.14MB
Number of channels: 4 channels.
Sensing method and temperature range: PT100.
A1S64TC series component is a kind of temperature controller combined with ANS series CPU.
Components with temperature measurement input and built-in PID algorithm control output, can be used in a variety of temperature control occasions A1SX80 Manual A1SX80 User's Manual.
Each component controls up to 4 loops at most.
Thermocouple input or PT100 3 wire temperature sensor input A1SX80
Control output switching signal for the output of the transistor.
BW is a signal with broken line detection function. Input voltage range: AC100 ~ 120V.
Output voltage: DC24V.
Output current: 0.6A.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage A1SX80 Manual A1SX80 User's Manual.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load A1SX80 Manual A1SX80 User's Manual.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30%.
The following describes the centralized control system I/O points of the estimate. MELSECNET/MINI (-S3) data link system, A2C system transfer converter.
Twisted pair cable - plastic optical fiber cable.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations.
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc..
MITSUBISHI PLC program simulation debugginng
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of thee program A1SX80 Manual A1SX80 User's Manual A1SX80 Manual A1SX80 User's Manual.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation.
Related products
MITSUBISHI
Input / output module
A1SX48Y18
MITSUBISHI Input / output module A1SX48Y18
Enter 8 points. 7mA DC24V. Response time: 12m
MITSUBISHI
Positioning control module
A1SD75P2-S3
MITSUBISHI Positioning control module A1SD75P2-S3
Axis of control: 2 axis linkage, 2 axis indep
MITSUBISHI
32: terminal line adapter
A1S-TA32-7
MITSUBISHI 32: terminal line adapter A1S-TA32-7
32: terminal line adapter 0.75mm2 AGW18.