Input and output points: 224 points.
Input / output data points: 224 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:0.25.
Internal storage RAM memory capacity: 64k.
Internal storage E2PROM memory capacity: 32k.
The popularization and application of PLC programming has been developed rapidly in our country,
It has been widely used in all kinds of mechanical equipment and production process of electrical control devices,
All walks of life have emerged a large number of application of PLC transformation of the results of the equipment A1SD75P1-S3 Manual A1SD75P1-S3 User's Manual A1SD75P1-S3
Understand the working principle of PLC, have the ability to design, debug and maintain the PLC control system,
Has become the basic requirements of modern industry for electrical technicians and engineering students A1SD75P1-S3 Manual A1SD75P1-S3 User's Manual.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC.
Structured text language is a programming language that describes a program with a structured description of the text A1SD75P1-S3 Manual A1SD75P1-S3 User's Manual.
It is a programming language similar to a high level language. In large and medium-sized PLC systems, structured text is often used to describe the relationship between the variables in the control system.
Mainly used for other programming languages more difficult to achieve the user program.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register.
And then combine the data and the program with CPU.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive. Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.25mA.
Output protection function.
Rated load voltage / current: DC24V/0.5A.
External connection: 3 line /2 linne type A1SD75P1-S3 Manual A1SD75P1-S3 User's Manual.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool A1SD75P1-S3 Manual A1SD75P1-S3 User's Manual.
Related products
MITSUBISHI
Positioning control module
A1SD75P2-S3
MITSUBISHI Positioning control module A1SD75P2-S3
Axis of control: 2 axis linkage, 2 axis indep
MITSUBISHI
Positioning control module
A1SD75P3-S3
MITSUBISHI Positioning control module A1SD75P3-S3
Axis of control: 3 axis linkage, 3 axis indep
MITSUBISHI
Positioning control module
A1SD75M2
MITSUBISHI Positioning control module A1SD75M2
Axis of control: 2. Interpolation function: 2
MITSUBISHI
Positioning module
A1SD71-S7
MITSUBISHI Positioning module A1SD71-S7
2 axes. 2 axis linear interpolation. Control