MITSUBISHI
Home >> Products >> MITSUBISHI >> QS safety series >> WS0-GCC100202 | MITSUBISHI CC-Link interface module WS0-GCC100202

WS0-GCC100202 | MITSUBISHI CC-Link interface module WS0-GCC100202

MITSUBISHI WS0-GCC100202 Manual And Instructions
WS0-GCC100202 datasheetPDF datasheet

MITSUBISHI WS0-GCC100202 Product information and technical parameters:
Brand: MITSUBISHI
Name: CC-Link interface module
Model: WS0-GCC100202
Transmission speed: 156kbps/625kbps/2.5Mbps/5Mbps/10Mbps (automatic tracking).
Station No.: 1~64 station.
External connection mode: 2 pieces of spring clip terminal.
Spring clip terminal.
The safety controller can communicate with the master station of the CCLINK system.
The data from the security controller to the master station can be edited by the parameters.
The security controller receives the data from the master station to set the tag name.
Transmission speed according to the automatic tracking station, do not need to set the transmission speed.
By using the spring clamping terminal, the wiring time and the maintenance time of the CC-Link cable can be reduced.
No need to re write parameters after replacement of the module.
The security controller can be set up and connected with the monitoring software.
Confirm the error record that is detected.

Application: extension.
Suitable for safety standards: EN954-1 class 4, PLe ISO13849-1.
Security input points: 1.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic MITSUBISHI WS0-GCC100202 WS0-GCC100202
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file. Board module installation location: QS series power module mounting slot.
Suitable substrate module: QS034B MITSUBISHI WS0-GCC100202.
Input power: AC100~120V.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards MITSUBISHI WS0-GCC100202.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down. Output points: 4 points (select the source type + drain type), 2 points (select the source type + source).
Isolation mode: photoelectric coupling.
Rated input voltage: DC24V.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed ouutside the standard control procedures WS0-GCC100202.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memoryy,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down WS0-GCC100202.


...More relevant models >>>>