MITSUBISHI
Home >> Products >> MITSUBISHI >> Q series PLC >> Input module >> QX42 | MITSUBISHI Type DC input module QX42

QX42 | MITSUBISHI Type DC input module QX42

MITSUBISHI QX42 Manual And Instructions
QX42 datasheetPDF datasheet
QX42 datasheetPDF datasheet
QX42 User's Manual

MITSUBISHI QX42 Product information and technical parameters:
Brand: MITSUBISHI
Name: Type DC input module
Model: QX42
Input points: 64 points.
Input voltage and current: 4mA DC24V.
Response time: 1/5/10/20/70ms.
32 point /1 a public side.
Common anode.
40 pin connector.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.

RS-422/485.
2 channel.
Transmission speed: 2 channels.
Total 230.4kbps.
Corresponding Configurator-SC Version2 GX.
Serial communication module capable of collecting and changing data of programmable controller, monitoring and managing, measuring data collection and so on.
Can achieve the highest speed of 230 MITSUBISHI QX42. 4kbps, the maximum of 960 words (MC protocol communications) of the high speed and large capacity communications QX42
Can use MC protocol, through the external devices (PC, monitors, etc.) to implement the data read / write programmable controller.
By selecting a non sequential protocol and use sequential program for communication control, the programmable controller and the external device (barcode reader and measurement equipment),
Communication with local protocols using external devices MITSUBISHI QX42.
QJ71C24N (-R2) through the RS-232 serial communication,
Programming and monitoring of programmable controllers using programming tools.
QJ71C24N (-R2) with the function of the modem corresponding to the public telephone line,
Can be used to initialize the modem, and the connection of the object device processing,
Communication with a remote device, a programming tool, a modem, and a public telephone line MITSUBISHI QX42.
Using remote password,
Can be prevented by QJ71C24N (-R2) function of the modem Q series programmable controller for illegal access. For A6TBXE/A6TBY36E/A6TBX54E/A6TBY54E/A6TBX70E (common cathode; source) long 1m.Three-phase 3 wire type.
Measuring circuit number: 1 circuits.
Measurement items: power consumption (consumption, regeneration), current, voltage, power, power factor, etc..
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information.
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment.
3 phase 3 wire products caan be used to measure up to 4 circuits in one slot,
3 phase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products QX42.
For example, a module ccan be used to measure other loads from the control panel trunk QX42.
In addition, Works2 GX (version 1.90U and higher) can be used to easily set parameters.


...More relevant models >>>>