Master / local station sharing.
IE CC-Link field network.
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module.
Using Ethernet cables and connectors available on the market to reduce costs.
High speed communication capable of communicating with 1Gbps.
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transmission delay time and the application of the synchronization waiting time.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX.
Can be in the Works2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation.
QJ71GF11-T2 can be used as the main station / local station of IE CC-Link field network.
Input points: 16 points.
Input voltage and current: 4mA DC24V.
Response time: 1/5/10/20/70ms.
16 point /1 a public side.
Common cathode.
18 point spring clip connection terminal.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password MITSUBISHI QJ71GF11-T2.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password
QJ71GF11-T2
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
Easy connection programming tool via ethernet MITSUBISHI QJ71GF11-T2.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection MITSUBISHI QJ71GF11-T2.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control.Express PCI bus.
Support japanese.
Ethernet cable.
Linear / star (linear and star can be mixed use)
Field network (control station / common station).
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station.
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between stations, the length of the total cable length, strong anti-interference.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network.
Twisted pair bus system...... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
AAble to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) QJ71GF11-T2.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmmission) communication separately, so as to ensure the timeliness of QJ71GF11-T2.
Even if the information reaches saturation, it will not affect the link scan time.