Function: 4CH voltage / current output.
Adapter for connecting the left extension function of the CPU module.
CPU module can be connected to the left side up to 6 units.
Apply PLC:FX2N (up to 3 units), FX3U (up to 3 units).
Applicable PLC:FX2NC (to FX2NC-CNV-IF, up to 1 units), FX3UC (to FX2NC-CNV-IF or FX3UC-1PS-5V, up to 3 units).
The rotation angle detecting unit is controlled by the mechanical cam switch,
The rotation angle is detected by using the special detector, and the rotation position control with high precision is realized MITSUBISHI FX5-4DA-ADP.
Using the setting unit, it is easy to realize the setting and monitoring of the action resolution
FX5-4DA-ADP
The detection of rotation angle can be accurate to the high accuracy of 415rpm/0.5 degree or 830rpm/1.0 degree unit.
Built without battery to maintain the EEPROM, the maximum can store 8 kinds of procedures.
The cable that is assembled in the device without the brush can be extended to 100m MITSUBISHI FX5-4DA-ADP.
When used alone, the CC-LINK type FX2N-32CCL interface module can be used to connect to the CC-LINK system.
Product composition:
FX2N-1RM: the main body of programmable cam switch (with setting panel).
F2-720RSV: no brush splitter.
FX2N-RS-5CAB: splitter cable (5m).
PLC connecting cable (55mm). Function: bus convert FX5 to FX3.
Input and output points: 8 points MITSUBISHI FX5-4DA-ADP.
Conversion module connecting FX3 series expansion module.
FX3 series expansion module, only the right side of the bus conversion module can be connected. Input and output points: 10 points.
Power supply: AC100-240V.
Input points: 6 points.
Output points: 4 points.
Output form: transistor output (drain).
Power consumption: 19W.
Weight: 0.3KG.
Outline dimension: 60x90x75mm.
A new application model.
FX3SA is a basic model on the basis of the basic performance of FX1S above the expansion of the expansion of the new model.
FX3SA is applicable to all kinds of fields of small scale equipment which need to simulate the quantity and function of MODBUS and Ethernet.
Basic models suitable for small scale control.
Compact but powerful,
At the same time, the analog quantity and communication function, etc.. Protocol: SLMP, TCP/IP, UDP, SNTP.
Communication mode: full duplex / half duplex.
At the same time can open a few: 4 connection FX5-4DA-ADP.
Weight: 0.3kg.
Can be low cost will be connected to the FX3 series Ethernet.
Support data monitoring, can monitor the basic unit through the computer browser,
Remote maintenance can be carried outt by Works2 GX in a place far from the scene FX5-4DA-ADP.
Connect FX3SA, FX3S, FX3GA, FX3G, FX3U host, you need to convert the adapter or function expansion board.