MITSUBISHI
Home >> Products >> MITSUBISHI >> FX series PLC >> FX2NC series >> FX2NC-64MT-DSS | MITSUBISHI PLC FX2NC-64MT-DSS

FX2NC-64MT-DSS | MITSUBISHI PLC FX2NC-64MT-DSS

MITSUBISHI FX2NC-64MT-DSS Manual And Instructions
FX2NC-64MT-DSS datasheetPDF datasheet
FX2NC-64MT-DSS HARDWARE MANUAL
FX2NC-64MT-DSS PROGRAMMING MANUAL II
FX2NC-64MT-DSS HARDWARE MANUAL

MITSUBISHI FX2NC-64MT-DSS Product information and technical parameters:
Brand: MITSUBISHI
Name: PLC
Model: FX2NC-64MT-DSS
Max input / output points: 64 points.
Power supply voltage: 24VDC.
Input points: 32 points.
Output points: 32 points.
Output type: Transistor (source).
Power consumption: 11W.
Weight (kg):0.35.
Size (WxHxD) mm:60x90x87.
Taking into account space saving and processing speed.
Connector input and output type compact high performance universal machine.
Compact, scalable input / output.
Can connect analog quantity, communication, positioning, etc..
Rich special extension equipment for FX2N.
By connecting the compact FX2rvc series with the input and output expansion module.
The input and output can be extended to 256 points.
Built in 8000 step RAM memory.
By installing the memory card box, the maximum can be extended to the 16000 step.
Overseas oriented products meet all kinds of international standards.
Use terminal module to replace connector connection or relay terminal row connection,
So as to save the wiring inside the cabinet.

Max input / output points: 32 points.
Power supply voltage: 24VDC.
Input points: 16 points.
Output points: 16 points.
Output type: relay.
Power consumption: 25W.
Weight (kg):0.65.
Size (WxHxD) mm:150x90x87.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time MITSUBISHI FX2NC-64MT-DSS FX2NC-64MT-DSS
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
Note recording function, Component annotation can be recorded in the program register.
Since the FX2n series have the following features: the maximum range of inclusive of the standard features, program execution faster, the full complement of communication function, suitable for different countries in the world, and the power to meet a large number of special function modules of individual needs,
It can provide maximum flexibility and control capability for your factory automation applications MITSUBISHI FX2NC-64MT-DSS.
Control 16~256 point.
Built in 8K capacity of the RAM memory, the maximum can be extended to 16K MITSUBISHI FX2NC-64MT-DSS.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable. Max input / output points: 80 points.
Supply voltage: 100 - 240VAC.
Input points: 40 points.
Output points: 40 points.
Output type: Transistor (source).
Power consumption: 50W.
Weight (kg):1.20.
Size (WxHxD) mm:285x90x86.
Built in CPU, power supply, input and output. By using a rich variety of functional extension boards and special adapters,
Can achieve high precision control.
Based on the function of FX2N has been greatly strengthened and enhanced.
High speed operation.
Basic instructions: 0.065 s/ instruction.
Application instruction: 0.642 s/ instruction.
Large capacity memory.
Built in program memory 64000 steps.
Flash memory cartridge with program transfer function.
Authentication。
Corresponding EN and UL/cUL authentication.
Faster and more efficient. Support high speed control and network communication, and have the function of data recording.
High speed, large capacity, multi-function high-end machine.
FX3U supports high speed processing, CC-Link communication, network communication, analog control and advanced positioning system.
Connected to the CC-Link, including the remote I/O, the maximum input and output control points up to 384 points,
Can correspond to a variety of field needs, the use of its scalability and flexibility to expand the scope of application of the control system.
Third generation high functioon micro programmable controller FX2NC-64MT-DSS.
High speed, high efficiency, high performance, large capacity, and new features.
Built in high speed processing and positioning.
Control points: maximum 256 points.
Use CC-Link remote I/O for 384 poinnts FX2NC-64MT-DSS.
Auxiliary relay: 7680 points.
Timer: 512 points.
Counter: 235.
Data register: 8000.
Extended register: 32768 point.
Extended file register: 32768.


...More relevant models >>>>