Memory format: EEPROM.
Number of steps: up to 16000 steps can be used.
Battery support: do not.
Method for writing and deleting: the device is installed on the PLC, and is written and deleted by the peripheral device.
Note: built-in extension.
The analog input adapter (FX3U- - racy -BD)Output points: 32 points.
Power supply: the basic unit to the expansion module to provide power.
Output form: transistor output (source).
Terminal type: connector type.
Weight: 0.2kg.
FX3GC, FX3UC can be directly connected to the input and output expansion equipment, to achieve a compact expansion MITSUBISHI FX2N-ROM-E1.
Can choose 16 points, 32 points of the relay or transistor input and output models
FX2N-ROM-E1
FX2NC-16E_-T-DS for terminal units can be disassembled models. Length: 1.5m.
Specification: TB-FX round cable. Input / output type: transistor output (source).
Output points: 16 points.
DC5V internal consumption current: 100mA.
DC24V internal consumption current: 125mA.
In order to extend the input output of the device MITSUBISHI FX2N-ROM-E1.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256.
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points. Total points: 32 points.
Input points: 16 points.
Input mode: DC24V (drain / source) MITSUBISHI FX2N-ROM-E1.
Output points: 16 points.
Output form: Transistor (source).
Connection status: connector.
In order to extend the input output of the device.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256.
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points. Input output cable for A6TBXY36 type connector / terminal row conversion module.
Length 3M. The adapter with PT100 type temperature sensor (FX3U- - racy -BD)Analog input points: 4 points (thermocouple, PT, constant voltage input).
Output points: transistor output 4 points, 4 point CT input.
Weight: 0.4KG.
Temperature sensor with 4CH input control output,
Double position control, standard PID control,
Heating and cooling PID control, cascade control.
By using the combination of the analog output module,
PID control of voltage or current can be realized FX2N-ROM-E1.
New with cascade control. Through the master / slave station of the 2 controllers,
According to the temperature change caused by external disturbance, the tempperature can be adjusted quickly FX2N-ROM-E1.
Can connect FX3GA/FX3G, FX3GE, FX3U series.
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-IPS-5V.