MITSUBISHI
Home >> Products >> MITSUBISHI >> FX series PLC >> FX2N series >> FX2N-80MS | MITSUBISHI PLC FX2N-80MS

FX2N-80MS | MITSUBISHI PLC FX2N-80MS

MITSUBISHI FX2N-80MS Manual And Instructions
FX2N-80MS datasheetPDF datasheet

MITSUBISHI FX2N-80MS Product information and technical parameters:
Brand: MITSUBISHI
Name: PLC
Model: FX2N-80MS
Max input / output points: 80 points.
Supply voltage: 100 - 240VAC.
Input points: 40 points.
Output points: 40 points.
Output type: silicon controlled.
Power consumption: 40W.
Weight (kg):1.2.
Size (WxHxD) mm:285x90x87.
Since the FX2n series have the following features: the maximum range of inclusive of the standard features, program execution faster, the full complement of communication function, suitable for different countries in the world, and the power to meet a large number of special function modules of individual needs,
It can provide maximum flexibility and control capability for your factory automation applications.
Control 16~256 point.
Built in 8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module.
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).

Total input and output points: 40 points.
Input points: 24 points.
Output points: 16 points.
Output type: relay output.
Power supply voltage: DC24V.
Input signal voltage: DC24V.
8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0.08 S/ basic instructions MITSUBISHI FX2N-80MS.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules FX2N-80MS
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable MITSUBISHI FX2N-80MS.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
Note recording function, Component annotation can be recorded in the program register MITSUBISHI FX2N-80MS.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program. Applicable models: FX3G\FX3GE\FX3GC\FX3U\FX3UC.
The contents of the RAM memory in FX2N-10GM, FX3UC, FX2N-20GM and FX3U are built up.
In addition, it is also required to use the backup relay and the data register and the time of the data register.
As FX3G, FX3GE, FX3GC with the option,
The use of soft components other than EEPROM. Input and output points: 20 points.
Power supply: AC100-240V.
Input points: 12 points.
Output points: 8 points.
Output form: transistor output (drain).
Power consumption: 20W.
Weight: 0.4KG.
Outline dimension: 75x90x75mm.
A new application model.
FX3SA is a basic model on the basis of the basic performance of FX1S above the expansion of the expansion of the new model FX2N-80MS.
FX3SA is applicable to all kinds of fields of small scale equipment which need to simulate the quantity and function of MODBUS and Ethernet FX2N-80MS.
Basic models suitable for small scale control.
Compact but powerful,
At the same time, the analog quantity and communication function, etc..


...More relevant models >>>>