Max input / output points: 30 points.
Power supply voltage: DC24V.
Input points: 16 points.
Output points: 14 points.
Output type: relay.
Power consumption (W): 21.
Weight (kg):0.45.
Size (WxHxD) mm:100x90x75.
Positioning and pulse output functions: a PLC cell can output 2 point 100KHz pulses at the same time.
Including zero return, absolute or relative address expression and special pulse output control.
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication.
Length: 3m.
Specification: D-sub 25 pin (male), D-sub 25 pin (male). Max input / output points: 16 points.
Power supply voltage: 24VDC.
Input points: 8 points.
Output points: 8 points.
Output type: Transistor (source).
Power consumption: 6W.
Weight (kg):0.2.
Size (WxHxD) mm:35x90x87.
Taking into account space saving and processing speed MITSUBISHI FX1S-30MR-D.
Connector input and output type compact high performance universal machine
FX1S-30MR-D
Compact, scalable input / output.
Can connect analog quantity, communication, positioning, etc..
Rich special extension equipment for FX2N.
By connecting the compact FX2rvc series with the input and output expansion module.
The input and output can be extended to 256 points.
Built in 8000 step RAM memory MITSUBISHI FX1S-30MR-D.
By installing the memory card box, the maximum can be extended to the 16000 step.
Overseas oriented products meet all kinds of international standards.
Use terminal module to replace connector connection or relay terminal row connection,
So as to save the wiring inside the cabinet. Input points: 36 points.
Output points: 24 points.
Power supply voltage: AC240-360V.
Output type: transistor output (drain) MITSUBISHI FX1S-30MR-D.
A free combination of PLC.
FX3G basic unit: 14/24/40/60 point.
FX3GA is a compact PLC, simple design and with the basic functions of the FX3 series.
Through the strengthening of the built-in function and flexible expansion, expanded in various fields of application.
Third generation standard model.
High flexibility.
Suitable for small scale control of high cost.
Control points to 128 points, the use of CC-Link remote I/O can control the maximum 256 points.
High speed operation.
Basic instructions: 0.21 s/ instruction.
Application instruction: 0.5 s/ instruction.
Large capacity memory.
Built in program memory 32000 steps.
EEPROM memory cartridge with program transfer function. Function: input / output module (internal service power supply).
Input / output points: 32 points
Input points: 16 points.
Output points: 16 points.
DC5V internal consumption current: 965mA.
DC24V internal consumption current: 250mA. FX1S-30MR-D.
Input / output mode: DC input (drain / source) / relay output.
In order to extend the input output of the device.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256.
Expansion modulee: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points FX1S-30MR-D.