MITSUBISHI
Home >> Products >> MITSUBISHI >> Inverter >> FR-F800 series inverter >> FR-F840 inverter 3 phase 400V >> FR-F842-12120-2-60 | MITSUBISHI Rectifying partial off type frequency converter FR-F842-12120-2-60

FR-F842-12120-2-60 | MITSUBISHI Rectifying partial off type frequency converter FR-F842-12120-2-60

MITSUBISHI FR-F842-12120-2-60 Manual And Instructions
FR-F842-12120-2-60 datasheetPDF datasheet

MITSUBISHI FR-F842-12120-2-60 Product information and technical parameters:
Brand: MITSUBISHI
Name: Rectifying partial off type frequency converter
Model: FR-F842-12120-2-60
MITSUBISHI inverter series: FR-F842.
Voltage level: three phase 400V.
Power: 560kw.
SLD converter rated current: 1212A.
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
Energy saving by high efficiency motor.
Reduce standby power consumption.
DC24V external power supply, the input MC signal can be stopped after the motor for the OFF, in the motor drive for the ON.
Standby power management can be carried out by means of frequency converter to realize the power consumption reduction of standby time.
According to the temperature of the inverter cooling fan, the operation of the inverter can be controlled.
According to the operating conditions of the inverter cooling fan output the corresponding signal,
Therefore, the inverter and other built-in fan and inverter cooling fan synchronous operation.
Can reduce the power consumption in the stop.

MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 1.5KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible MITSUBISHI FR-F842-12120-2-60 FR-F842-12120-2-60
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced MITSUBISHI FR-F842-12120-2-60.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft. "MITSUBISHI inverter series: FR-A846.
Voltage level: three phase 400V.
Power: 1.5kw.
SLD converter rated current: 5.2A.
Structure and function: IP55 counterpart.
Type: CA.
Substrate coating: have.
Built in DC reactor.
Easy to operate, simple settings MITSUBISHI FR-F842-12120-2-60.
We have prepared a series of equipment and functions for you to work in any place to meet the life cycle of the product.
Allegedly, the motor power consumption accounted for about half of the total power generated by manufacturing industry consumption.
How to achieve energy efficiency in the plant without affecting the productivity.
Less energy consumption and more output FR-A800 series inverter will help you to have both fish and bear''s paw"
Parameters and frequency settings can be modified in the program.
Inverter control, for example, by the input signal to trigger the operation of the inverter, based on the operation of the inverter
The status of the signal output, as well as the monitor output and so on, can be customized according to the requirements FR-F842-12120-2-60.
The control of each machine can be done separately by the frequency converter, and the controol of the dispersion is also carried out FR-F842-12120-2-60.
Through combining with the real-time clock function can realize the automatic operation (in option FR-LU08). "


...More relevant models >>>>