MITSUBISHI
Home >> Products >> MITSUBISHI >> Inverter >> FR-F700 series inverter >> FR-F740 inverter 3 phase 400V >> FR-F740-7.5K-CHT | MITSUBISHI 3 phase 400V converter FR-F740-7.5K-CHT

FR-F740-7.5K-CHT | MITSUBISHI 3 phase 400V converter FR-F740-7.5K-CHT

MITSUBISHI FR-F740-7.5K-CHT Manual And Instructions
FR-F740-7.5K-CHT datasheetPDF datasheet
FR-F740-7.5K-CHT AppliedInstruction manual
FR-F740-7.5K-CHT BASICInstruction manual
FR-F740-7.5K-CHT TECHNICAL MANUAL

MITSUBISHI FR-F740-7.5K-CHT Product information and technical parameters:
Brand: MITSUBISHI
Name: 3 phase 400V converter
Model: FR-F740-7.5K-CHT
"MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 7.5KW.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency, the device is the first power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter. "

The output signal can open collector output inverter host standard.
Can be from the voltage output terminal (AM0), the current output terminal (AM1) output analog signal (output frequency, output current, etc.).
Can be connected to the 20mA DC or 10V DC meter. "MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V MITSUBISHI FR-F740-7.5K-CHT.
Frequency converter capacity: 560KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor FR-F740-7.5K-CHT
Why is the frequency of the inverter voltage proportional to the change?
The electromagnetic torque of any motor is the result of the interaction between the current and the magnetic flux, the current is not allowed to exceed the rated value, otherwise it will cause the heating of the motor MITSUBISHI FR-F740-7.5K-CHT.
Therefore, if the magnetic flux decreases, the electromagnetic torque will decrease, which leads to the reduction of the load carrying capacity MITSUBISHI FR-F740-7.5K-CHT. Superior high efficiency IPM motor.
Output power: 55kw.
Rated speed: 1500r/min.
Voltage level: 200V.
IPM motor MM-EFS series can not be used to run the power frequency power.
The total wiring length of the IPM motor shall not exceed 100m.
1 inverters can not connect multiple IPM motors at the same time. "MITSUBISHI inverter FR-F720P series.
Voltage level: three phase 200V.
Frequency converter capacity: 1.5KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%).
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mainly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FR-F740-7.5K-CHT.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FR-F740-7.5K-CHT. "


...More relevant models >>>>