MITSUBISHI FR-E740-0.75K-CHT Product information and technical parameters:
Brand: MITSUBISHI
Name: 3 phase 400V converter
Model: FR-E740-0.75K-CHT
MITSUBISHI inverter FR-E740 series.
Voltage level: 3 phase 400V.
Frequency converter capacity: 0.75KW.
Allow short-time overload (200% 3S).
The machine itself does not need to purchase another operating panel.
Provide USB interface to connect with the computer, you can use the FRConfigurator software to set the parameters of the inverter or monitor.
Inverter surface with PU interface, FR-E500 operating panel can be directly connected to the E700 series. The installation dimensions are in full agreement with FR-E500.
Allow side by side installation, saving installation space
Simple maintenance: equipped with comb type wiring board, wiring more convenient, the replacement of the same series inverter, no stitches, as long as the original inverter control terminal.

Power: 15kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor MITSUBISHI FR-E740-0.75K-CHT.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table FR-E740-0.75K-CHT
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling.
MYS type resistor can be used. But please pay attention to the allowable brake use rate.
Do not remove the terminal P/+ and P1 between the short circuit chip, in addition to connecting the DC reactor MITSUBISHI FR-E740-0.75K-CHT.
The installation of thermal relay, to avoid overheating and burn the braking resistor. "MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 11KW.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency, the device is the first power of the AC power conversion to DC (DC), the process is called rectification MITSUBISHI FR-E740-0.75K-CHT.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter. "Used to reduce radio noise.MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 90KW.
When the ring is opened, the frequency converter is provided with a load of the motor when the motor is operated with a load at a given frequency,
The range of the motor speed in the rated slip ratio (1%~5%) changes.
For the requirements of relatively high precision, even if the load chhanges are also required to operate at a given speed of the occasion,
Inverter with PG feedback function can be used (selection) FR-E740-0.75K-CHT.
If the given acceleration time is too short, the output frequency of the inverter is far more than thhe change of the speed (electric angular frequency),
Converter will be due to flow over the current trip, the operation stopped, which is called stall FR-E740-0.75K-CHT.