MITSUBISHI
Home >> Products >> MITSUBISHI >> Inverter >> FR-A700 series inverter >> FR-A740 inverter 3 phase 400V >> FR-A740-0.4K-CHT | MITSUBISHI 3 phase 400V converter FR-A740-0.4K-CHT

FR-A740-0.4K-CHT | MITSUBISHI 3 phase 400V converter FR-A740-0.4K-CHT

MITSUBISHI FR-A740-0.4K-CHT Manual And Instructions
FR-A740-0.4K-CHT datasheetPDF datasheet
FR-A740-0.4K-CHT PLC FUNCTION PROGRAMMING MANUAL
FR-A740-0.4K-CHT BASICINSTRUCTION MANUAL
FR-A740-0.4K-CHT AppliedINSTRUCTION MANUAL
FR-A740-0.4K-CHT TECHNICAL MANUAL

MITSUBISHI FR-A740-0.4K-CHT Product information and technical parameters:
Brand: MITSUBISHI
Name: 3 phase 400V converter
Model: FR-A740-0.4K-CHT
MITSUBISHI inverter FR-A740 series.
Voltage level: 3 phase 400V.
Frequency converter capacity: 0.4KW.
FR-A700 converter products are suitable for all kinds of high load requirements of the equipment.
Such as lifting, lift, printing and dyeing, printing and dyeing, material coiling and other general occasions.
High level driving performance.
Unique sensorless vector control mode,
A wide variety of mechanical equipment can be operated at high precision in the super low speed region without the need of the encoder.
With torque control mode,
And in the speed control mode can use the torque limit function.
With vector control function (with encoder),
Frequency converter can achieve position control and fast response, high precision speed control (zero speed control, servo lock, etc.) and torque control.

Used to reduce radio noise.Power: 15kw.
Voltage: 400V.
There are 100% braking torque output in continuous regeneration, which can correspond to the continuous regeneration operation of the pipeline control.
There is no need to install the braking unit for each frequency converter, which can reduce the comprehensive space and reduce the comprehensive cost MITSUBISHI FR-A740-0.4K-CHT.
Renewable energy can be used for other frequency converter, excess energy back to the grid, to achieve energy saving FR-A740-0.4K-CHT Purpose: to operate, monitor, and change the parameters through the network.
Applicable frequency converter: FR-A700, FR-F700, FR-E700. The frequency of a transducer can be set by a digital signal from an external BCD or binary code MITSUBISHI FR-A740-0.4K-CHT.
BCD code 3 (maximum 999).
BCD code 4 (maximum 9999).
Binary code 12 (max FFFH).
Binary code 16 (max FFFFH). "MITSUBISHI inverter FR-F740P series.
Voltage level: three phase 400V.
Frequency converter capacity: 500KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor MITSUBISHI FR-A740-0.4K-CHT.
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mainly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FR-A740-0.4K-CHT.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FR-A740-0.4K-CHT. "


...More relevant models >>>>