MITSUBISHI
Home >> Products >> MITSUBISHI >> L series PLC >> FA products >> FA-LEB32XY-3 | MITSUBISHI Conversion module FA-LEB32XY-3

FA-LEB32XY-3 | MITSUBISHI Conversion module FA-LEB32XY-3

MITSUBISHI FA-LEB32XY-3 Manual And Instructions
FA-LEB32XY-3 datasheetPDF datasheet

MITSUBISHI FA-LEB32XY-3 Product information and technical parameters:
Brand: MITSUBISHI
Name: Conversion module
Model: FA-LEB32XY-3
Convert connectors to e-CON.

Can be isolated to obtain DC24/48/100V, AC100/200V input signal.Output points: 32 points.
Output type: leakage type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 32 points (I/O distribution: output 32 points) MITSUBISHI FA-LEB32XY-3.
External wiring connection mode: 40 pin connector.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called FA-LEB32XY-3
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch MITSUBISHI FA-LEB32XY-3.
Communication protocol is a standard Modbus protocol or custom protocol. Can be used as a screw relay terminal. Positive common end use.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output MITSUBISHI FA-LEB32XY-3. Input points: 8 points.
Rated input voltage: AC100 ~ 120V.
Common way: 8 point / public end.
Input / output occupied points: 16 points (I/O distribution: 16 points).
External wiring connection: 18 point terminal.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarrm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the part can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on FA-LEB32XY-3 FA-LEB32XY-3. The terminal row is converted to e-CON.


...More relevant models >>>>