MITSUBISHI
Home >> Products >> MITSUBISHI >> CC-Link module >> CC-link spare parts >> CL1PSU-2A | MITSUBISHI Dedicated power supply CL1PSU-2A

CL1PSU-2A | MITSUBISHI Dedicated power supply CL1PSU-2A

MITSUBISHI CL1PSU-2A Manual And Instructions
CL1PSU-2A datasheetPDF datasheet
CL1PSU-2A User's Manual
CL1PSU-2A User's Manual

MITSUBISHI CL1PSU-2A Product information and technical parameters:
Brand: MITSUBISHI
Name: Dedicated power supply
Model: CL1PSU-2A
Input voltage rating: AC100/120/230/240V
External connection mode: module power supply: Terminal 3 pin (M3 screw), communication line / module power supply unit.
Dedicated power supply for CC-LINK/LT system with built-in 2A power supply.

Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 0.2ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/0 MITSUBISHI CL1PSU-2A. 1A.
External connection: 1 line /1 line type.
Fast connector type CL1PSU-2A
Simple wiring through quick connector.
Can be installed along the 6 direction.
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program MITSUBISHI CL1PSU-2A.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation. Output type: transistor output, source.
Output points: 16 points.
OFF leakage current: 0.30mA.
Output protection function.
Rated load voltage / current: DC12V/DC24V/0.1A.
External connection: 2 wire.
Waterproof connector type MITSUBISHI CL1PSU-2A.
Strong waterproof type of IP67 protection grade.
No need to stop the system can be replaced module.
Without the use of tools can be a simple connection, save time.
Terminal resistor built-in.
Can be installed along the 6 direction.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy to guarantee the timeliness.
Simulation of the process of debugging, debugging method can be usedd to segment, and the monitoring function of programmer CL1PSU-2A. Input type: DC input, positive common end.
Input points: 4 points.
Input response time: 0.5ms below /1.5ms.
Rated input voltage / current: DC24V/4mA.
External connection: 3 wire.
Sennsor connection type CL1PSU-2A.
Minimum size of industry.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input.