MITSUBISHI AS91 Product information and technical parameters:
Brand: MITSUBISHI
Name: Modular
Model: AS91

Number of channels: 2 channels.
Sensing method and temperature range: PT100.
A1S64TC series component is a kind of temperature controller combined with ANS series CPU.
Components with temperature measurement input and built-in PID algorithm control output, can be used in a variety of temperature control occasions MITSUBISHI AS91.
Each component controls up to 4 loops at most.
Thermocouple input or PT100 3 wire temperature sensor input AS91
Control output switching signal for the output of the transistor.
BW is a signal with broken line detection function. 4 channel analog input module.
A1S64AD analog input module can accept the voltage or current signal,
The built-in microprocessor converts these signals to binary values,
For the control program to enjoy MITSUBISHI AS91.
Signal can be instantaneous read, can also be programmed time / frequency average,
The offset and gain value can be set, and this component also includes the following performance:
4 input channels.
High resolution digital output.
Total accuracy plus or minus 1%. Temperature sensor: PT100, 4 wire system.
The A1S62RD3 and A1S62RD4 temperature sensor input modules allow the platinum resistance temperature sensing element to be directly connected to the PLC,
This component converts a signal from a temperature measuring element to a numeric value that represents a temperature measurement value,
This temperature value can be used for the control process MITSUBISHI AS91.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of.
The response time of PLC is the interval between the time of the change of the external output signall of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the usse of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on AS91 AS91.
This phenomenon is called the I/O delay time effect.