MITSUBISHI
Home >> Products >> MITSUBISHI >> CC-Link module >> Remote I/O module >> AJ65SBTB1-16T | MITSUBISHI Transistor output module AJ65SBTB1-16T

AJ65SBTB1-16T | MITSUBISHI Transistor output module AJ65SBTB1-16T

MITSUBISHI AJ65SBTB1-16T Manual And Instructions
AJ65SBTB1-16T datasheetPDF datasheet

MITSUBISHI AJ65SBTB1-16T Product information and technical parameters:
Brand: MITSUBISHI
Name: Transistor output module
Model: AJ65SBTB1-16T
Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.25mA.
Output protection function.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 1 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool.

Output type: transistor output, drain type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC12V/DC24V/0.1A.
External connection: 2 wire.
Spring clip terminal.
Do not need to re tighten, suitable for wire specifications for 0.3~1.5MM square MITSUBISHI AJ65SBTB1-16T.
Terminal block is 2 piece structure.
An input module shared by the common terminal of the positive and negative AJ65SBTB1-16T
The 8 point of the output module is appended to the source type.
Can be installed along the 6 direction. Input type: DC input, positive public end / negative public end.
Input points: 8 points.
Enter the response time: 0.5ms/1.5ms the following.
Rated input voltage / current: DC24V/4mA MITSUBISHI AJ65SBTB1-16T.
External connection: 2 wire.
Screw terminal table type.
Minimum size of industry.
The connection object at a glance with terminal cover plate.
Input module for public end of positive pole and negative pole.
Terminal table structure capable of connecting with 2 wire type sensor and load in the same condition.
Can be installed along the 6 direction.
Output type: transistor output, drain type MITSUBISHI AJ65SBTB1-16T.
Output points: 32 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC12V/DC24V/0.1A.
By embedding the product into the customer base, the remote I/O station can be simply developed.
Mitsubishi Co PLC network inherited the traditional use of the MELSEC network,
And make it better in terms of performance, function, easy to use etc..
Provides a layer of three layers of clear network, to provide the most suitable network products for a variety of uses.
The information layer /Ethernet (Ethernet) information layer is the highest level of the network system,
Mainly in the PLC, the device controller and production management with PC transmission between production management information, quality management information and the operation of equipment, etc.,
Information layer using the most common Ethernet.
It is not only able to connect the PC system UNIX, windows system, etc.,
And can connect a variety of FA devices.
The Etthernet module has the function of Internet e-mail receiving and sending,
The user can send and receive the production information conveniently in any place of the world,
Build a remote monitoring management system AJ65SBTB1-16T.
At the same time, tthe use of the Internet FTP server functions and MELSEC protocol can be very easy to achieve the program upload / download and transfer of information AJ65SBTB1-16T.


...More relevant models >>>>