MITSUBISHI
Home >> Products >> MITSUBISHI >> CC-Link module >> CC-link spare parts >> A6CON-PW5P-SOD | MITSUBISHI Quick connector plug for power supply and FG A6CON-PW5P-SOD

A6CON-PW5P-SOD | MITSUBISHI Quick connector plug for power supply and FG A6CON-PW5P-SOD

MITSUBISHI A6CON-PW5P-SOD Manual And Instructions
A6CON-PW5P-SOD datasheetPDF datasheet

MITSUBISHI A6CON-PW5P-SOD Product information and technical parameters:
Brand: MITSUBISHI
Name: Quick connector plug for power supply and FG
Model: A6CON-PW5P-SOD
A pack of 10.
Applicable models:
AJ65VBTS - - - type.
AJ65VBTCE - - - type.
AJ65VBTCU - - - type.
AJ65ABTP - - - type.
AJ65VBCU- - type.

Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/0 MITSUBISHI A6CON-PW5P-SOD. 1A.
External connection: 1 line /1 line type.
Fast connector type A6CON-PW5P-SOD
Simple wiring through quick connector.
Can be installed along the 6 direction.
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program MITSUBISHI A6CON-PW5P-SOD.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation. Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 0.2ms below, below 1.5ms, 5ms below, 10ms the following.
Rated input voltage / current: DC12V/11mA.
Output form: transistor output, leakage type MITSUBISHI A6CON-PW5P-SOD.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/0.5A.
External connection: 3 line /2 line type.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool. Output type: relay output.
Output points: 4 points.
OFF leakage current: -.
Output protection function: No.
Rated load vooltage / current: DC30V/AC250V/2A A6CON-PW5P-SOD.
External connection: 2 wire.
Screw terminal table type.
Minimum size of industry.
The connection object at a glance with terminal cover plate.
Input module for public end of positive pole and negativve pole A6CON-PW5P-SOD.
Terminal table structure capable of connecting with 2 wire type sensor and load in the same condition.
Can be installed along the 6 direction.


...More relevant models >>>>