MITSUBISHI
Home >> Products >> MITSUBISHI >> A/QnA series PLC >> CPU >> A2CCPU-DC24V | MITSUBISHI cpu module A2CCPU-DC24V

A2CCPU-DC24V | MITSUBISHI cpu module A2CCPU-DC24V

MITSUBISHI A2CCPU-DC24V Manual And Instructions
A2CCPU-DC24V Common InstructionsProgramming Manual
A2CCPU-DC24V User's Manual
A2CCPU-DC24V HardwareUser's Manual
A2CCPU-DC24V Dedicated InstructionsProgramming Manual
A2CCPU-DC24V FundamentalsProgramming Manual

MITSUBISHI A2CCPU-DC24V Product information and technical parameters:
Brand: MITSUBISHI
Name: cpu module
Model: A2CCPU-DC24V

Category: slave station.
Transfer speed: 125kbps/250kbps/500kbps/1Mbps.
Transmission line form: bus system.
Total distance: 125kbps:1000m/250kbps:800m/500kbps:480m/1Mbps:240m.
The maximum connection units: 32.
Total points: input + output <=2048 point.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures MITSUBISHI A2CCPU-DC24V.
These procedures are relatively independent, generally in the basic completion of the program design and then add A2CCPU-DC24V
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations. Output points: 32 points.
Voltage: DC12/24V MITSUBISHI A2CCPU-DC24V.
OFF leakage current: 0.1mA.
Output type: transistor output (type sink).
Response time: 2ms.
38 point terminal station.
With heat protection.
With the surge absorber.
With short circuit protection.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal MITSUBISHI A2CCPU-DC24V.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
Control solenoid valve required I/O points by the action principle of the solenoid valve can bbe known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points A2CCPU-DC24V A2CCPU-DC24V.


...More relevant models >>>>