MITSUBISHI
Home >> Products >> MITSUBISHI >> Ans/QnAs series PLC >> Computer communication module >> A1SJ71UC24-R2 | MITSUBISHI Computer communication module A1SJ71UC24-R2

A1SJ71UC24-R2 | MITSUBISHI Computer communication module A1SJ71UC24-R2

MITSUBISHI A1SJ71UC24-R2 Manual And Instructions
A1SJ71UC24-R2 datasheetPDF datasheet
A1SJ71UC24-R2 User's Manual
A1SJ71UC24-R2 HardwareUser's Manual

MITSUBISHI A1SJ71UC24-R2 Product information and technical parameters:
Brand: MITSUBISHI
Name: Computer communication module
Model: A1SJ71UC24-R2
Interface: RS232C.
Transmission distance: 15 meters.
A1SJ71UC24-R2/R4/PR computer communication components can communicate with PLC, such as computers and other external intelligent devices, and the components are as follows:
Full / half duplex transmission.
4 special communication protocols.
No protocol and bidirectional mode.
Protocol selection switch function.
The optional baud rate, the highest 19.2K.
Since the echo diagnostic test.

10BASE-T.
The structured text programming language uses the computer description method to describe the various kinds of relations between the various variables in the system,
Complete the required function or operation.
Most PLC manufacturers use structured text programming language similar to BASIC language, PASCAL language or C language and other advanced languages,
But in order to be convenient, the expression methods of the statement and the types of statements are simplified MITSUBISHI A1SJ71UC24-R2 A1SJ71UC24-R2
Structured text programming language features: the use of high-level language programming, you can complete the complex control operations,
Need to have a certain level of computer knowledge and programming skills,
Higher requirements for engineering designers MITSUBISHI A1SJ71UC24-R2. Poor visibility and operability.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order MITSUBISHI A1SJ71UC24-R2.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three.
PLC is introduced by the relay control technology after the development of micro processing technology,
Can be easily and reliably used for switching control.
As the analog quantity can be converted into digital quantity, the number of digital quantity is just a number of switching value,
Therefore, after the conversion of analog, PLC can also be reliable for processing control.
Because the continuous production process often has the analog quantity, the analog quantity control is sometimes called process control.
Analog quantity is not electricity, and PLC can only handle digital quantity, quantity of electricity.
All to realize the conversion between them to have the sensor, the analog quantity into a number of power.
If this power is not standard, but also through the transmitter,
The non-standard power into a standard electrical signal, such as 1-5V, 4-20mA, 0-10V, etc..
At the same time, there is also an analog input unit (A/D),
Transform these standard electrical signals into digital signals,
The analog output unit (D/A), in order to transform the digital quantity after PLC processing into analog quantity -- standard electric signal.
So the standard telecommunication number, the conversion between the number of operations to use a variety of computing.
This requires the resolution of the analog unit and thee standard electrical signal A1SJ71UC24-R2.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, tthe fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of A1SJ71UC24-R2.


...More relevant models >>>>