A0J2E-E28DR | MITSUBISHI Extension module A0J2E-E28DR

MITSUBISHI A0J2E-E28DR Manual And Instructions
A0J2E-E28DR datasheetPDF datasheet
A0J2E-E28DR User's Manual

MITSUBISHI A0J2E-E28DR Product information and technical parameters:
Brand: MITSUBISHI
Name: Extension module
Model: A0J2E-E28DR

Output points: 32 points.
Voltage: AC100 ~ 240V.
OFF leakage current: 3mA.
Output type: bidirectional controlled silicon.
Response time: 0.5Hz+1ms.
8 points / a common end.
38 point terminal station.
With short circuit protection.
With the surge absorber.
Each scanning process. Focus on the input signal sampling MITSUBISHI A0J2E-E28DR. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read A0J2E-E28DR
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program MITSUBISHI A0J2E-E28DR.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive MITSUBISHI A0J2E-E28DR.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear. Adapter for mounting rails. Unit connection CPU unit.Remote I/O controller, optical fiber.
How to choose MITSUBISHI PLC.
MITSUBISHI PLC options include the choice of MITSUBISHI PLC models, capacity, I/O module, power, etc..
MITSUBISHI PLC distribution I/O points and design MITSUBISHI PLC peripheral hardware circuit
Draw the I/O point of the PLC and the input / output device connection diagram or the corresponding table,
This part also can be carried out in second steps.
Designn PLC peripheral hardware circuit A0J2E-E28DR.
Draw the electrical wiring diagram of the other parts of the system,
Including the main circuit and the control circuit does not enter the PLC, etc..
The electrical schematic diagram of the system compoosed of I/O PLC connection diagram and PLC peripheral electrical circuit diagram A0J2E-E28DR.
So far the system''s hardware electrical circuit has been determined.