Servo motor series: medium inertia, small capacity.
Rated output: 5.0kw.
Rated speed: 2000r/min.
Electromagnetic brake: No.
Oil seal: incidental (Note 1, note 2, note 3).
Power supply: 200V.
Note 1 through HG-KR and HG-MR series 0.1kW and HG-SR series can be supported.
Note 2 with the speed reducer case, do not configure the oil seal.
Note 3 with oil seal HG-KR, HG-MR series servo motor''s appearance size standard is different
Q4ARCPU
Stable driving of medium capacity and medium inertia type products.
Through the optimization of structural design, to achieve the minimum length of the industry.
High speed & high torque. Shorten the positioning time, achieve high-speed equipment.
Reducing the electric torque ripple.
Through the combination of the optimal number of the motor and the slot number, the torque ripple is greatly reduced,
To further realize the smooth constant speed device.
Improve the environmental performance of HG-SR, HG-JR series of products using IP67. Servo motor series: low inertia, medium and large capacity.
Rated output: 11.0kw.
Rated speed; 1500r/min.
Electromagnetic brake: No.
Power supply: 200V.
Most suitable for medium and large capacity, low inertia type products in high frequency operation or acceleration and deceleration operation.
Improve the environmental performance of HG-SR, HG-JR series of products using IP67.
High speed & high torque. Shorten the positioning time, achieve high-speed equipment.
100 scene, there are 100 different drive control.
In order to meet the needs of the diverse and detailed field,
MR-J4 product line configuration, providing a wealth of servo amplifier and servo motor products.
Can meet the different needs of different customers. 3C-2V/5C-2V coaxial cable between the single bus PC network (control station / common station) / remote I/O network (remote master).
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on.
This phenomenon is called the I/O delay time effect.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three.