Type of input: DC leakage.
Input points: 32 points.
Input voltage: DC24.
Input current: 7mA.
Connection mode: terminal row.
Common common point: 32.
Functional block diagram language is a kind of PLC programming language, which is similar to digital logic circuit.
The function module is used to represent the function of the module,
Different function modules have different functions.
Functional module figure programming language features: functional block diagram programming language is characterized by a functional module for the unit,
Analysis and understanding of the control scheme is simple and easy: function module is to use graphical form of expression,
Intuitive, for a digital logic circuit based on the design of the staff is very easy to master the programming;
Control system with complex scale and complex control logic,
Because the function module diagram can clearly express the function relation, the programming debugging time is greatly reduced
MR-J2HBUS05M Motor series: low inertia, small capacity.
Using a serial absolute / incremental encoder.
Rated output power: 0.05kw.
Rated speed: 3000rpm.
With the brake with brake.
Without GB.
Shaft end: straight shaft.
A servo motor is an engine that controls the operation of the mechanical components in the servo system.
Servo motor can make the control speed, position accuracy is very accurate, can be converted to torque and speed voltage signals to drive the control object.
Servo motor rotor speed is controlled by the input signal, and can quickly response,
In the automatic control system, used as actuators, and electromechanical time constant, high linearity, initiating voltage characteristics,
The signal can be converted into a motor shaft on the angular displacement or angular velocity output.
Divided into DC and AC servo motor two major categories, the main features are,
When the signal voltage is zero, there is no rotation,
The speed increases with the increase of the torque and the speed decreases. Category: slave station.
Transfer speed: 125kbps/250kbps/500kbps/1Mbps.
Transmission line form: bus system.
Total distance: 125kbps:1000m/250kbps:800m/500kbps:480m/1Mbps:240m.
The maximum connection units: 32.
Total points: input + output <=2048 point.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations.
MR-J2HBUS05M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MR-J2HBUS05M&select=5